Справочник Пользователя для Mitsubishi Electronics E60

Скачать
Страница из 415
8. SPINDLE 
PARAMETERS 
8.1 
Spindle Base Specifications Parameters 
II - 229 
 
Items 
Details 
Setting range (Unit)
3066 spdiv6 
Magnification 
for 
time constant 
changeover speed 
Set the acceleration/deceleration time 
constant between the spindle 
synchronization multi-step 
acceleration/deceleration changeover 
speed 6 (sptc6) to the spindle 
synchronization multi-step 
acceleration/deceleration changeover 
speed 7 (sptc7) as a magnification in 
respect to the spindle synchronization 
acceleration/deceleration time constant 
(spt). 
0 to 127 
3067 spdiv7 
Magnification 
for 
time constant 
changeover speed 
Set the acceleration/deceleration time 
constant for the spindle synchronization 
multi-step acceleration/ 
deceleration changeover speed 7 (sptc7) 
and higher as a magnification in respect to 
the spindle synchronization 
acceleration/deceleration time constant 
(spt). 
0 to 127 
3068 symtm1  Phase 
synchroniza- 
tion start 
confirmation time 
Set the time to confirm that synchronization 
is attained before phase synchronization 
control is started. 
When "0" is set, the time will be 2 seconds. 
When "100" or less is set, the time will be 
100ms. 
0 to 9999 (ms) 
3069 symtm2  Phase 
synchroniza- 
tion end 
confirmation time 
Set the time to wait for phase 
synchronization control to end as the time 
for the rotation speed to reach the 
attainment range. 
When "0" is set, the time will be 2 seconds. 
When "100" or less is set, the time will be 
100ms. 
0 to 9999 (ms) 
3070 syprt 
Phase 
synchroniza- 
tion speed 
Set the fluctuation amount to change the 
synchronous spindle rotation speed during 
phase synchronization control as the 
command speed and rate. 
When "0" is set, the amount will be 100%. 
0 to 100 (%) 
3071  
(Not 
used.) 
 
 
3072  
(Not 
used.)