Справочник Пользователя для Mitsubishi Electronics E60

Скачать
Страница из 415
8. SPINDLE 
PARAMETERS 
8.2 MDS-B-SPJ2 
II - 230 
8.2 MDS-B-SPJ2 
For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters will be 
valid after the power is turned ON again.  
The valid spindle parameters will differ according to the motor and amplifier type. Follow the correspondence 
table given below, and set the correct parameters. 
The spindle parameter setting and display method will differ according to the NC being used, so refer to 
Instruction Manual for each NC and the following spindles. 
MELDAS AC Servo and Spindle MDS-A Series MDS-B Series Specifications Manual ... BNP-B3759 
The "fixed control constants" and "fixed control bits" in this section are set by Mitsubishi.  
!
CAUTION 
!
  Do not make remarkable adjustments or changes of the parameters as the operation may 
become unstable. 
!
  In the explanation on bits, set all bits not used, including blank bits, to "0". 
 
No. Items 
Details 
Setting 
range 
Standard 
setting 
3201 SP001 
PGM  Magnetic 
detector and 
motor built- 
in encoder 
orientation- 
mode position 
loop gain 
As the set value is larger, the orientation time 
becomes shorter and servo rigidity is 
increased. 
On the contrary, however, vibration is 
increased and the machine becomes likely 
to overshoot. 
0 to 1000 
  (0.1 1/s) 
100 
3202 SP002 
PGE  Encoder 
orientation-mo
de position 
loop gain 
As the set value is larger, the orientation time 
becomes shorter and servo rigidity is 
increased. 
On the contrary, however, vibration is 
increased and the machine becomes likely 
to overshoot. 
0 to 1000 
  (0.1 1/s) 
100 
3203 
 
SP003  
Not used. Set to "0". 
0 0 
3204 SP004 
OINP Orientation 
in-position 
width 
Set the position error range in which an 
orientation completion signal is output.  
1 to 2880 
  (1/16°) 
16 
3205 
(PR) 
SP005 OSP 
Orientation 
mode 
changing 
speed limit 
value 
Set the motor speed limit value to be used 
when the speed loop is changed to the 
position loop in orientation mode. 
When this parameter is set to "0", SP017 
(TSP) becomes the limit value. 
0 to 32767 
  (r/min) 
3206 SP006 
CSP  Orientation 
mode dece- 
leration rate 
As the set value is larger, the orientation time 
becomes shorter. On the contrary, however, 
the machine becomes likely to overshoot. 
1 to 1000 
20 
3207 SP007 
OPST In-position 
shift amount 
for orientation 
Set the stop position for orientation. 
Set the value by dividing 360° by 4096. 
0 to 4095 
3208 
 
SP008 
 
Not used. Set to "0". 
3209 SP009 
PGT  Synchronous 
tapping 
position loop 
gain 
Set the spindle position loop gain in 
synchronous tapping mode.  
1 to 100 
(1/s) 
15