COMPACT V2.0 E 
16 
 
the OUTPUT less it’s give to the charger. Priority for the OUTPUT. When the power sharing is 
used the LED 200% (red) is lit to point out that’s the charge is limited. 
 
Caution:
 If the power use on the OUTPUT is higher than the value of the INPUT LIMIT (26) 
the COMPACT    limit the current, then the generator means to stop or the circuit breaker 
before means to break. 
In option, a remote control (RPS-01, 20m cable) allows the Power Sharing far from the COMPACT.  
4.6.3.1  Set the INPUT LIMIT (26) 
The current available for the COMPACT depend of the supply used 
i.e. motor generator, network limit in a camping or shore 
connections… The value of the turning knobs INPUT LIMIT (26) 
must by adjust lower or equal of the current available from the 
source.  
For example if you have a generator of 2kW you must adjust the 
turning knobs 26 to approximately 8.5A. For calculate this, we 
divide the nominal power (2000W) by the voltage (230V). If you 
have a circuit breaker (i.e. 6A) before the COMPACT, then you set 
this value on the turning knobs (26) (i.e. 6A). 
4.6.4 Charging 
current: 
The maximum charging current for the battery can be adjusted with the Turning Knob 22 
(CHARGER). The charging current of the battery should be set to approximately 10 – 20% of the 
battery capacity (at C10). This means that the charging current for a battery with 300Ah should be 
set between 30 – 60A.  
The charging current is displayed on CURRENT MONITOR (25) of the front panel or on the 
Remote Control  . 
4.6.5 Battery 
Condition:  
Built-in microprocessor with a specially developed 
algorithm calculates the actual state of charge  of the 
battery and displays it on LED 15 – 18. The LED 14 is 
lit  when the system is carrying out a charge cycle with 
equalization. 
For safety reasons, you must get the recommended 
charge voltage and charge currents from your battery 
supplier. The voltage levels and charge characteristics 
can be changed through Programming. The instruction 
for programming of battery charger is in the section 
„Programming“(Chap.  5.1.2). The correct charging is 
indispensable for a safe function and long-life of the 
battery. 
4.7 The Transfer system 
When an ac voltage is at the input AC IN of the COMPACT, the LED 1 AC IN is lit. When this 
voltage matches the lowest adjusted value set by the Turning Knob 23 TRANSFER, and the 
frequency is between  44Hz and 65Hz, this voltage is switched directly to the battery charger and 
to the output AC OUT. The LED 7 TRANSFER is lit. The inverter is switched off and the battery 
charger switched on. This process is automatic, unless the charger mode or the transfer mode is 
disabled (see Chap. 5.5) 
 
The maximum current of the Transfer switch is 15A. That means through this system, consuming 
devices up to a maximum of al 3500 Watt can be operated. When the Battery Charger is working, 
part of this power is used for the charging according with the power sharing system.  
The Transfer system is protected against overload with an automatic  safety fuse on the AC Input 
side of the COMPACT. If the system has been overloaded  the  button/pin of the fuse will pop-out. 
To put the automatic safety system back in to operating you must push this pin back.  
Generator 
power 
Current 
(230V) 
500W 2A 
900W 4A 
1500W 6,5A 
2000W 8,5A 
3000W 13A 
 
 
14
15
16
17
18
Equalization cycle 
Battery 75 – 100% 
Battery 50 – 75% 
Battery 25 – 50% 
Battery 0 – 25%