Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
1 - 9 
MELSEC-A
1   PRODUCT OUTLINE 
 
Speed V
Pulse droop
amount
Pulse 
distribution
Servomotor 
speed
Accel-
eration
Decel-
eration
Time t
Stop 
settling time
Pulse train Rough
Dense
Rough
 
Fig. 1.3   D75P2 output pulses 
 
V
R
L
P0
P
Pulse encoder
(PLG)
Workpiece
Worm gear
Table
Servomotor
 
A  :  Movement amount per pulse (mm/pulse) 
Vs  :  Command pulse frequency (pulse/s) 
n  :  Pulse encoder resolution (pulse/rev) 
L  :  Worm gear lead (mm/rev) 
R : Deceleration 
ratio 
V  :  Movable section speed (mm/s) 
N  :  Motor speed (r/min) 
K  :  Position loop gain (1/s) 
  :  Deviation counter droop pulse amount 
P0 :  Zero point (pulse) 
P : Address 
(pulse)
 
Fig. 1.4   System using worm gears 
 
(1)   
Movement amount per pulse
 
 
A = 
[mm/pulse] 
 n 
 
(2)   Command pulse frequency 
 
Vs = 
[pulse/s] 
 
(3)   Deviation counter droop pulse amount 
 
 = 
Vs 
[pulse] 
 
The movement amount per pulse is indicated with (1), and the [No. of output pulses]  
[
movement amount per pulse]
 is the movement amount. The command pulse frequency is 
calculated with (2) using the movable section speed and 
movement amount per pulse
The relation of the command pulse frequency and deviation counter droop pulses is 
shown in (3). 
 
As the positioning command 
unit
, (mm), (inch), (degree) or (pulse) can be selected 
independently for the 1 to 2 axes of the D75P2. 
Thus, if the data such as the movement amount per pulse, acceleration/deceleration 
time, positioning speed, and positioning address are set to match the positioning 
command unit, the operation will be carried out within the D75P2 for the target 
positioning address. The pulse train will be output, and positioning will be executed.