9 - 12 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
[When the speed cannot change over in P2] 
When the relation of the speeds is P1 = 
P4, P2 = P3, P1 < P2. 
 
[When the movement amount is small during 
automatic deceleration] 
The movement amount required to carry out the 
automatic deceleration cannot be secured, so the 
machine immediately stops in a speed  0 status. 
P1
P2
P3
P4
 
 
Positioning address.
 
 
2)  Front-loading speed changeover mode 
 
(1)  When the "positioning data for current operation" and "positioning 
data for next operation" differ in command speed, acceleration or 
deceleration starts during positioning executed with the 
"positioning data for current operation", and the speed set in the 
"positioning data for next operation" is reached at completion of 
the positioning. 
 
(2)  The parameters used in acceleration/deceleration to the 
command speed set in the "positioning data to carry out the next 
operation" are those of the positioning data to carry out 
acceleration/deceleration. 
Speed changeover will not be carried out if the command speeds 
are the same.  
 
OFF
ON
OFF
ON
OFF
ON
OFF
ON
11
11
11
01
00
V
Dwell time
t
Da. 1 O
peration pattern 
Start complete signal
BUSY signal
Positioning complete signal
Positioning start signal
Positioning
[RY(n+1)0, RY(n+1)1]
[RXn1, RXn2]
[RXn4, RXn5]
[RXn7, RXn8]
Dwell time
Fig. 9.5 Operation for the front-loading speed changeover mode