Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
9 - 13 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
(3)  Speed changeover condition 
If the movement amount is small in regard to the target speed, the 
current speed may not reach the target speed even if 
acceleration/deceleration is carried out. In this case, the machine 
is accelerated/decelerated so that it nears the target speed.  
If the movement amount will be exceeded when automatic 
deceleration is required (Ex. Operation patterns "00", "01"), the 
machine will immediately stop at the positioning address, and a 
warning "insufficient movement amount" (warning code: 513) will 
occur.  
 
[When the speed cannot change over to the 
P2 speed in P1] 
When the relation of the speeds is P1 = 
P4, P2 = P3, P1 < P2. 
 
[When the movement amount is small during 
automatic deceleration] 
The movement amount required to carry out the 
automatic deceleration cannot be secured, so the 
machine immediately stops in a speed  0 status. 
P1
P2
P3
P4
 
 
Positioning address