9   MAIN POSITIONING CONTROL 
 
9.1.3 Designating the positioning address 
The following shows the two methods for commanding the position in control using 
positioning data. 
 
 Absolute system 
 
Positioning is carried out to a designated position (absolute address) having the 
zero point as a reference.    This address is regarded as the positioning address. 
(The start point can be anywhere.)   
 
Address
100
Address
150
Address
300
100
A point
150
B point
300
C point
Within the stroke limit range
Address 150
Address
100
Address 100
Address 150
Zero point
(reference point)
Start point 
End point 
·
 
Fig. 9.6 Absolute system positioning 
 
 
 Increment system  
 
The position where the machine is currently stopped is regarded as the start point, 
and positioning is carried out for a designated movement amount in a designated 
movement direction.   
 
Movement amount
+100
Movement
amount -150
Movement amount
-100
Movement amount+50
100
150
300
Movement amount-100
A point
B point
Within the stroke limit range
C point
Movement amount
+100
Movement amount +100
Start point 
End point 
·
 
Fig. 9.7 Increment system positioning