10 - 13 
MELSEC-A
10   ADVANCED POSITIONING CONTROL 
"Error". 
<4>  After the execution of the axis 1 "positioning data No. 50" is completed, stop 
the control. 
10.3.6 Stop 
In a "stop", the control is stopped with the "start block data" set in "4: stop". 
The control after the point in which the "stop" is set can be restarted by issuing a 
"Restart command (RY(n+2)5, RY(n+4)5)".   
 
Section (2) shows a control example where the "start block data" and "positioning data" 
are set as shown in section (1).   
 
(1)   Setting examples 
 
(a)      Start block data setting example 
 
Axis 1 start 
block data 
Da.10  Shape
Da.11  Start 
data No. 
Da.12  Special 
start command 
Da.13  
Parameter 
1st point 
1: Continue 
0: Normal start 
– 
2nd point 
1: Continue 
10 
4: Stop 
– 
3rd point 
0: End 
50 
0: Normal start 
– 
 
 
 
 
 
 
 
 
 
 
 
(b)      Positioning data setting example 
 
Axis 1 position-
ing data No. 
Da.1  Operation pattern 
01: Continuous positioning control
01: Continuous positioning control
3 00: 
Positioning 
complete 
 
 
10 
11: Continuous path control 
11 
11: Continuous path control 
12 00: 
Positioning 
complete 
 
 
50 00: 
Positioning 
complete 
 
 
 
(2)   Control examples 
The following shows the control executed when the "start block data" of the 1st 
point of axis 1 is set as shown in section (1) and started.   
 
<1> Execute the axis 1 "positioning data No. 1, 2, and 3" and stop the control.   
 
<2>  After executing a "restart", execute the axis 1 "positioning data No. 10, 11, 
12, and 50", and stop the control.