Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
12 - 47 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
12.6 Absolute position restoration function 
CAUTION
 
When absolute position restoration is performed, the servo ON signal may turn OFF 
(the servo may switch off) for about 20ms, starting the motor. If any inconvenience 
may be caused by the start of the motor when the servo ON signal turns OFF, provide 
an electromagnetic brake separately to lock the motor with the electromagnetic brake 
during absolute position restoration. 
 
The "absolute position restoration function" is designed to restore the absolute position 
of the specified axis. This function eliminates the need for a zero point return after 
power-off, such as an instantaneous power failure or emergency stop, ensuring ease 
of on-site restoration work. 
The following details of the "absolute position restoration function" will be explained. 
   (1) Configuration and preparation of absolute position detection system 
   (2) Outline of absolute position detection data communication 
   (3) Connection example 
   (4) Precautions during control 
 
[1] Configuration and preparation of absolute position detection system 
 
(1) Configuration 
The configuration of the absolute position detection system is shown below. 
Refer to the servo amplifier manual for details of connection with the servo 
amplifier. 
 
Servo
amplifier
Power supply
Detector cable
Absolute position holding battery
Control signal connector
1)
2)
3)
Servomotor with absolute position detector
D75P2
PLC
CPU
4)
Connection cable
Ma
st
er
mo
du
le
 
Fig. 12.31 Configuration of absolute position detection system