12 - 48 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
(2) Preparation 
Note the details in the following table for preparation of the absolute position 
detection system. 
 
System component 
Details 
1) Servo amplifier 
(MR-H-A, MR-J2-A, MR-J2S-A)
 Fit the battery (MR-BAT, A6BAT) to the servo amplifier. 
 Make the servo amplifier side absolute position detection 
function valid. 
For other details, refer to the servo amplifier side instruction 
manual. 
2) Servomotor 
(HA-   H     -Y type) 
 Use the servomotor equipped with absolute position 
detector. 
For other details, refer to the servomotor side instruction 
manual. 
3) Detector cable 
 Add the connection of the battery power supply (BAT, LG 
signals) to the wiring of the incremental detector cable. 
For other details, refer to the cable side instruction manual. 
4) Connection cable 
Use the user-fabricated cable or following dedicated cable. 
 AD75C20SNH, AD75C20SNJ2 
 
[2] Outline of absolute position detection data communication 
 
As shown in the system block diagram of Fig. 12.32, the detector consists of the 
encoder, which detects a position within one revolution in addition to the A/B/Z-phase 
signals for position control during normal operation, and the cumulative revolution 
counter that detects the number of revolutions. 
This absolute position detection system always detects the absolute position of a 
machine and stores it by battery backup, independently of whether the PLC system 
power is ON or OFF. Therefore, once an initial zero point setting is made at the time of 
machine installation, no zero point return at power-on will be required after that, 
ensuring ease of restoration at an instantaneous power failure or emergency stop. 
Backed up by the super capacitor in the detector, the absolute position data is retained 
within the specified time if the cable is disconnected or broken. 
 
D75P2
Servo amplifier
Pulse train
command
Zero point data
Backup at
power off
E
2
PROM memory
LS0
1X0
Within-one-
revolution
position
detection
LS
Number of 
revolutions
detection
Servomotor
Within-one-revolution counter
(Detector)
1pulse/rev cumulative revolution 
counter
Super capacitor
Battery
Current feed 
value
Machine feed
value
Input
Output
Current
position
1X
S
pee
d co
ntro
l
P
osi
tion
 cont
rol
High-speed serial communication
A B Z-phase signals
 
Fig. 12.32 Outline of absolute position restoration function