MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
12.7 Other functions 
Other functions include the "step function", "skip function", "M code output function", 
"teaching function", "command in-position function", "stepping motor mode function", 
"acceleration/deceleration processing function" and "indirectly specification function". 
Each function is executed by parameter setting or sequence program creation and 
writing.  
 
12.7.1 Step function 
The "step function" is used to confirm each operation of the positioning control one by 
one.  
It is mainly used in debugging work for positioning control, etc. 
A positioning operation in which a "step function" is used is called a "step operation".  
In step operations, the timing for stopping the control can be set. (This is called the 
"step mode".) Control stopped by a step operation can be continued by setting "step 
continue" (to continue the control)" or restarted by setting "restart" in the "step start 
information".  
 
The details shown below explain about the "step function".  
  (1) Relation between the step function and various controls 
  (2) Step mode 
  (3) Step start information 
  (4) Using the step operation  
  (5) Control details 
  (6) Precautions during control 
  (7) Step function settings 
 
 
(1)   Relation between the step function and various controls 
The following table shows the relation between the "step function" and various 
controls. 
 
Control type 
Step function 
Step applicability 
Zero point 
return control 
Machine zero point return control 
Step operation not possible 
Data setting method zero point return 
High-speed zero pint return control 
Main 
positioning 
control 
Position 
control 
1-axis linear control 
Step operation possible 
2-axis linear interpolation control 
1-axis fixed-dimension feed control 
2-axis fixed-dimension feed control 
(interpolation) 
 
2-axis circular interpolation control 
Speed control 
Step operation not possible 
Speed/position changeover control 
Step operation possible 
Other 
control 
Current value change 
JUMP command 
Manual 
control 
JOG operation 
Step operation not possible 
Manual pulse generator operation 
 
                   : Set when required.   : Setting not possible