(2)   Step mode 
In step operations, the timing for stopping the control can be set. This is called 
the "step mode". (The "step mode" is set in the control data "
Cd.27  Step 
mode".) 
The following shows the two types of "step mode" functions.  
 
(a)   Deceleration unit step 
The operation stops at positioning data requiring automatic deceleration. (A 
normal operation will be carried out until the positioning data requiring 
automatic deceleration is found. Once found, that positioning data will be 
executed, and the operation will then automatically decelerate and stop.)  
 
(b)   Data No. unit step  
The operation automatically decelerates and stops for each positioning 
data. (Even in continuous path control, an automatic deceleration and stop 
will be forcibly carried out.) 
 
(3)   Step start information 
Control stopped by a step operation can be continued by setting "step continue" 
(to continue the control) or restarted by setting "restart" in the "step start 
information".  (The "step start information" is set in the control data " Cd.28  Step 
start information".)  
The following table shows the results of starts using the "step start information" 
during step operation.  
(Warnings will only be output when the step valid flag is ON.) 
 
Stop status in the step 
operation 
Axis operation status 
(RWrn+7, RWrn+15)
Cd.28  Step start 
information 
Step start results 
1 step of positioning 
stopped normally 
Step standing by 
1: Step continue 
The next positioning data is executed. 
2: Restart 
A "step start information invalid warning" 
occurs. 
Control stopped by a stop 
signal 
Step stopped 
1: Step continue 
A restart is carried out at the positioning 
data where the control was stopped. 
2: Restart 
An error occurred, and 
the control stopped 
Step error occurring 
1: Step continue 
A "step start information invalid warning" 
occurs. 
2: Restart 
 
The following warnings will occur if the "Axis operation status (RWrn+7, 
RWrn+15)" is not appropriate when step start information is set.  
 
Axis operation status (RWrn+7, RWrn+15) 
Step start results 
Standing by 
Step start information invalid 
warning 
Stopped 
Error occurring 
In interpolation 
Start during operation warning 
In JOG operation 
In manual pulse generator operation 
Analyzing 
Waiting for special start 
In zero point return 
In position control 
In speed control 
In speed control of speed/position changeover control 
In position control of speed/position changeover control