Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
14 - 4 
MELSEC-A
14   TROUBLESHOOTING 
 
14.2 Error and warning details 
(1)   Errors  
 
  Types of errors 
 
Errors detected by the D75P2 include parameter setting range errors and errors at 
the operation start or during operation.   
 
(1)  Parameter setting range errors 
The parameters are checked at the rising edge (OFF 
  ON) of the remote 
station READY signal [RX(n+7)B].   
An error will occur if there is a mistake in the parameter setting details at that 
time.  
When this kind of error occurs, the D75P2 READY signal does not turn OFF.   
To cancel this kind of error, set the correct value in the parameter for which 
the error occurred, and then turn ON the remote station READY signal 
[RX(n+7)B]. 
 
(2)  Errors at the operation start or during operation 
These are errors that occur at the operation start or during operation when 
using positioning control, JOG operation, manual pulse generator operation, 
etc. If an axis error occurs during interpolation operation, the error No. will be 
stored in both the reference axis and the interpolation axis.   
Note that in the following cases (a) and (b), the axis error No. will only be 
stored in the reference axis during analysis of the positioning data set in each 
point of the positioning start data table.   
      (a) When the interpolation axis is BUSY 
      (b) When the error occurred in positioning data or parameters unrelated to 
interpolation control. 
 
If the error occurred at the simultaneous start of a positioning operation, the 
axis error storage details will differ depending on whether the error occurred 
before or after the simultaneous start.     
 If the error occurred before the simultaneous start (illegal axis No., other axis 
BUSY, etc.), an "error before simultaneous start" will occur.   
 If the error occurred after the simultaneous start (positioning data error, 
software stroke limit error, etc.), an error code corresponding to the axis in 
which the error occurred will be stored.    Because a simultaneous start 
cannot be carried out due to this, a "simultaneous start not possible error" 
error code will be stored in all axes in which an error has not occurred.   
 
The axis operation status will be displayed as "error occurring" for axes in 
which an error occurred.   
If an error occurs during operation, any moving axes will deceleration stop, 
and their operation status will be displayed as "error occurring". 
Both axes will decelerate to a stop during interpolation operations, even if the 
error occurs in only one axis.   
 
(3)  Types of error codes 
 
Error code 
Error type 
001 to 009 
Fatal error 
010 to 099 
Error at selection of stepping motor mode 
100 to 199 
Common error 
200 to 299 
Error at zero point return 
300 to 399 
Error during JOG operation 
500 to 599 
Error during positioning operation 
900 to 999 
Error during parameter setting range check