Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
14 - 5 
MELSEC-A
14   TROUBLESHOOTING 
 
 Error storage 
 
When an error occurs, the error detection signal turns ON, and the error code 
corresponding to the error details is stored in the "Axis error No. (RWrn+5, 
RWrn+13)". Note that there is a delay of up to 56.8ms after the error detection 
signal turns ON until the error code is stored.   
 
Axis No. 
Error detection signal 
Remote register 
1 RXnA  RWrn+5 
2 RXnB  RWrn+13 
 
A new error code is stored in the "Axis error No. (RWrn+5, RWrn+13)" for axis 
error storage every time an error occurs.   
 
 
(2)   Warnings 
 
  Types of warnings 
 
(1)  Warning detection includes system warnings and axis warnings.   
The types of system warnings are shown below.   
 
  System control data setting errors   
An axis warning for axis 1 will occur.   
 
  Positioning data setting errors 
An axis warning for each axis will occur.   
Note that a warning will occur for the following axes when an interpolation 
designation or axis setting error occurs.   
 
(2)  Axis warnings occur due to setting warnings from operations such as 
positioning operations, JOG operations, manual pulse generator operations, or 
system errors. They can be canceled by turning ON the "Axis error reset 
(RY(n+2)4, RY(n+4)4)". 
Note that some warnings cannot be canceled unless the cause of the warning 
is eliminated.   
The axis operation status does not change even if an axis warning occurs.   
 
(3)  Types of warning codes 
 
Warning code 
Error type 
100 to 199 
Common warning 
300 to 399 
Warning during JOG operation 
400 to 499 
Warning during manual pulse generator operation 
500 to 599 
Warning during positioning operation 
900 to 999 
Warning during system control data range check