Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
14 - 38 
MELSEC-A
14   TROUBLESHOOTING 
 
Division of 
warning 
Warning 
code 
Warning name 
Description 
Action at occurrence of warning 
 
 
 
 
Positioning 
operation 
500 
Deceleration and 
stop speed 
change 
A speed change request is issued during 
deceleration and stop. 
Speed change is not carried out. 
 
501 
Speed limit value 
over 
The new speed value given during operation 
exceeds the speed limit value. 
 The speed is controlled to the “speed limit 
value.” 
 The “in speed limit flag” is turned ON. 
 
 
 
 
 
 
 
 
 
503 
M code ON 
signal ON start 
The M code ON signal is turned ON during 
execution of positioning data. 
Execution of positioning data continues. 
 
 
 
505 
No operation end 
setting 
In the block start positioning operation, the 
setting at 50th point in the positioning start 
data indicates continuation. 
Operation is terminated. 
 
 
 
 
506 
FOR to NEXT 
nesting structure 
There is a nested set of FOR and NEXT. 
Operation continues. 
 
508 
Speed/position 
changeover 
signal ON during 
acceleration 
The changeover signal is turned ON during 
acceleration under speed/position changeover 
control. 
509 
Insufficient 
remaining 
distance 
The deceleration distance for a speed change 
request is insufficient. 
A speed change occurs at the nearest value. 
(However, the request is ignored if the 
operation pattern is continuous path control.) 
 
511 
Invalid step start 
information 
“2: Restart” is specified for the step start 
information in the “in step wait” axis operation 
status. 
Step operation does not start. 
 
“1: Step continue” or “2: Restart” is specified in 
the step start information in the “step error 
occurring,” “error occurring,” “waiting,” or 
“stopped” axis operation status. 
512 
Illegal external 
start function 
The “external start function selection” setting in 
detail parameter 2 exceeds the setting range. 
Nothing occurs in response to the external start 
signal. 
 
513 
Insufficient 
movement 
amount 
There is no movement amount necessary for 
automatic deceleration. 
Immediate stop after the positioning address is 
reached 
 
514 
Outside 
command speed 
range 
The command speed exceeds the speed limit 
value. 
 The command speed is controlled to the 
“speed limit value.” 
 The “in speed limit flag” is set. 
 
 
 
 
 
 
 
System 
control data 
900 
Illegal clock data 
setting 
The clock data is written when the clock data 
setting is out of the setting range. 
The clock data is not written.