14   TROUBLESHOOTING 
 
14.5 Start during error history 
If an error occurs when starting, all the data in the buffer memory start history area 
(address: 462 to 541) is copied to the start during error history area (addresses: 543 to 
622).  
 
The data stored in the start during error history area is lost when the power is turned 
OFF.  
(When the power is turned ON, a "0" is stored in the start during error history.) 
 
Up to 16 start history items from turning the power ON can be stored in the start during 
error history area.   
(The previous history items are cleared in order from No. 1 when the No. of history 
items is exceeded.)   
 
The start during error history can be monitored with a peripheral device. 
 
 
Refer to the AD75 Software Package Operating Manual for details on operation of the 
peripheral device.   
 
< Example of display on the peripheral device > 
No. Axis 
Start 
Type 
Time  Judgment 
1 1  External 
100  21:34:56.7 OK 
2 2 
PC 
Manual pulse generator 
21:43:12.3 OK 
3 2 
PC 
JOG  21:43:34.4 201 
4 1  External Restart 
100 
21:43:54.8 OK 
5 3 Peripheral  101  10:18:03.7 201