Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
14 - 39 
MELSEC-A
14   TROUBLESHOOTING 
 
 
Relevant buffer memory address 
remote input/output device, or remote 
register 
Setting range 
Remedy 
Axis 1 
Axis 2 
 RY(n+2)7 
RY(n+4)7 
<Speed change request> 
ON: Speed change request 
Do not change the speed during deceleration or 
stoppage caused by a stop command or during 
automatic deceleration under position control. 
 
New speed value 
<New speed value, speed limit value> 
<In standard mode> 
1 to 1000000 [pulse/s] 
1 to 600000000 [mm/min, etc.] 
<In stepping motor mode> 
1 to 62500 [pulse/s] 
1 to 37500000 [mm/min, etc.] 
  [In case of new speed value, the 
minimum setting is “0.”] 
Change the new speed to a value within the range from 
0 to the “speed limit value.” 
RWwm+4 
RWwm+5 
RWwm+12 
RWwm+13 
Speed limit value 
6, 7 
156, 157 
 RY(n+2)6 
RY(n+2)6 
<M code OFF request> 
ON: The M code ON signal is turned 
OFF. 
Correct the ON/OFF timing of the “M code OFF 
request.” (Refer to section 12.7.3) 
 
Refer to section “5.3 List of positioning 
data.” 
<Operation pattern> 
00: Positioning complete 
01: Continuous positioning control 
11: Continuous path control 
Specify the end of operation at the 50th point. (Refer to 
Chapter 10) 
 
 
 
 
 
Reduce the FOR to NEXT nesting structure to one. 
(Refer to section 10.3.9) 
 
 
 
 
 
 
 
Do not turn ON the speed/position changeover signal 
during acceleration. 
(Refer to section 9.2.9) 
 
 
 
 
 
 
Issue a speed change request at a position where the 
sufficient remaining distance is left. 
 
 
 
 
 
 
 
1174 1224 
<Step start information> 
0: End of reception of step start 
1: Step continue 
2: Restart 
Do not specify “1: Step continue” in the “step waiting” 
axis status. 
Do not specify “1: Step continue” or “2: Restart” in the 
“step error occurring,” “error occurring,” “waiting,” or 
“stopped” axis operation status. 
 62  212 
<External start function selection> 
0, 1, 2 
Change “external start function selection” in detail 
parameter 2 to within the setting range. 
 
 
 
Refer to section “5.3 List of positioning 
data.” 
 
Change the positioning data to an address or 
movement amount sufficient for deceleration. 
 
Refer to section “5.3 List of positioning 
data” for the command speed. 
<Command speed, speed limit value> 
<In standard mode> 
1 to 1000000 [pulse/s] 
1 to 600000000 [mm/min, etc.] 
<In stepping motor mode> 
1 to 62500 [pulse/s] 
1 to 37500000 [mm/min, etc.] 
Change the command speed to within the setting 
range. 
Speed limit value 
6, 7 
156, 157 
 
1100 
1101 
Hours: 00 to 23 
Minutes: 00 to 59 
Seconds: 00 to 59 
Enter settings within the setting range in BCD codes.