Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
3 - 6 
MELSEC-A
3   SPECIFICATIONS AND FUNCTIONS 
 
3.3 List of functions   
3.3.1 D75P2 control functions 
The D75P2 has several functions. In this manual, the D75P2 functions are categorized 
and explained as follows. 
 
 Main functions 
 
(1)  Zero point return control 
 
"Zero point return control" is a function that established the start point for 
carrying out positioning control, and carries out positioning toward that start 
point. This is used to return a workpiece, located at a position other than the 
zero point when the power is turned ON or after positioning stop, to the zero 
point. The "zero point return control" is preregistered in the D75P2 as the 
"Positioning start data No. 9001 (Machine zero point return)", "Positioning start 
data NO. 9901 (Data setting method zero point return)" and "Positioning start 
data No. 9002 (High-speed zero point return). (Refer to "Chapter 8 ZERO 
POINT RETURN CONTROL".) 
 
(2)  Main positioning control 
 
This control is carried out using the "Positioning data" stored in the D75P2. 
Such as position control and speed control, is executed by setting the required 
items in this "positioning data" and starting that positioning data. An "operation 
pattern" can be set in this "positioning data", and with this whether to carry out 
control with continuous positioning data (ex.: positioning data No. 1, No. 2, No. 
3, ...) can be set. (Refer to "Chapter 9 MAIN POSITIONING CONTROL".) 
 
(3)  Advanced positioning control 
 
This control executes the "positioning data" stored in the D75P2 using the 
"positioning start information". The following types of applied positioning 
control can be carried out. 
 
 Random blocks, handling several continuing positioning data items as 
"blocks", can be executed in the designated order. 
 "Condition judgment" can be added to position control and speed control. 
 The positioning data having the same No. and set for multiple axes can be 
started simultaneously. (Pulses are output simultaneously to multiple 
servos.) 
 The designated positioning data can be executed repeatedly, etc.,   
(Refer to "Chapter 10 ADVANCED POSITIONING CONTROL".) 
 
(4) Manual control 
 
By inputting a signal into the D75P2 from an external source, the D75P2 will 
output a random pulse train and carry out control. Use this manual control to 
move the workpiece to a random position (JOG operation), and to finely adjust 
the positioning (manual pulse generator operation), etc. (Refer to "Chapter 11 
MANUAL CONTROL".) 
 
 Auxiliary functions 
 
When executing the main functions, control compensation, limits and functions can 
be added. (Refer to "Chapter 12 CONTROL AUXILIARY FUNCTIONS".) 
 
 Common functions 
 
Common control using the D75P2 for "parameter initialization" or "backup of 
execution data" can be carried out. (Refer to "Chapter 13 COMMON 
FUNCTIONS".)