Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
3 - 23 
MELSEC-A
3   SPECIFICATIONS AND FUNCTIONS 
 
3.5 Remote registers 
The D75P2 has remote registers for transfer of data to/from the the master module. 
This section explains the assignment and data structure of the remote registers. 
 
(1)  Remote register assignment 
The following table indicates the remote register assignment. 
 
Remote register assignment 
 
Transfer direction 
Addresses 
Details Default 
value 
Axis 1 
Axis 2 
Master   remote 
RWwm RWwm+8 
Positioning 
start 
number 
RWwm+1 RWwm+9 
Positioning operation 
speed override 
100 
RWwm+2 RWwm+10 
New current value 
RWwm+3 RWwm+11 
RWwm+4 RWwm+12 
New speed value 
RWwm+5 RWwm+13 
RWwm+6 RWwm+14 
JOG speed 
RWwm+7 RWwm+15 
Remote   master 
RWrn RWwn+8 
Current feed value 
RWrn+1 RWwn+9 
RWrn+2 RWwn+10 
Feedrate 
RWrn+3 RWwn+11 
RWrn+4 
RWwn+12 
Valid M code 
RWrn+5 
RWwn+13 
Axis error number 
RWrn+6 RWwn+14 
Axis 
warning 
number 
RWrn+7 
RWwn+15 
Axis operation status 
 
m, n: Addresses assigned to the master module by station number setting