Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
3 - 22 
MELSEC-A
3   SPECIFICATIONS AND FUNCTIONS 
 
Device 
No. 
Signal name 
Details 
RY(n+2)7 
RY(n+4)7 
Axis 1 
Axis 2 
Speed 
change 
request 
OFF  : No speed change 
request 
ON : 
Speed 
change 
requested 
  When changing the speed during positioning operation, turn this signal ON 
after setting a new speed value. 
  This signal executes a speed change on its rising edge. 
RY(n+2)8 
RY(n+4)8 
Axis 1 
Axis 2 
Speed/positi
on 
changeover 
enable flag 
OFF: Speed/position 
changeover 
disable 
ON: Speed/position 
changeover enable
When the speed/position changeover enable flag is turned ON, the 
speed/position changeover signal (RX(n+1)A, RX(n+4)A) is made valid. 
RY(n+2)9 
RY(n+4)9 
Axis 1 
Axis 2 
Manual 
pulse 
generator 
enable flag 
OFF: Manual pulse 
generator 
operation disable 
ON: Manual pulse 
generator 
operation enable 
This signal is used to set whether manual pulse generator operation is to be 
enabled or disabled. 
RY(n+2)A 
RY(n+4)A 
Axis 1 
Axis 2 
Zero point 
return 
request flag 
OFF 
request 
OFF: No zero point return 
request OFF 
request 
ON: Zero point return 
request OFF 
requested 
This signal turns OFF the zero point return request flag (RX(n+1)F, 
RX(n+4)F). 
This signal turns OFF the zero point return request flag on its rising edge. 
RY(n+2)B 
RY(n+4)B 
Axis 1 
Axis 2 
External 
start valid 
OFF: External start invalid
ON: External start valid 
When this signal turns ON, an external start is made valid. 
Initial data processing complete 
RY(n+7)8 Initial data 
processing 
complete 
OFF: Initial data 
processing 
incomplete 
ON: Initial data processing 
complete 
When Initial data setting request (RY(n+7)9) turns ON after power-on or a 
hardware reset, initial data setting is performed, and when it is completed, 
this signal turns ON. 
Initial data setting request flag 
RY(n+7)9  Initial data setting 
request flag 
OFF: No initial data 
setting request 
ON: Initial data setting 
requested 
This signal turns ON when initial data setting or change is performed. 
 
Fig. 3.1 shows the timings of the input/output signals, such as Initial data processing 
request and Initial data processing complete, of the D75P2. 
 
(1) Initial data setting 
Executed by D75P2
Executed by sequence program
RX(n+7)8
Initial data processing request
RY(n+7)8
Initial data processing complete
RX(n+7)9
Initial data setting complete
RY(n+7)9
Initial data setting request
RX(n+7)B
Remote station READY
 
 
(2) Data change or block transmission 
Executed by D75P2
Executed by sequence program
RX(n+7)9
Initial data setting complete
RY(n+7)9
Initial data setting request
RX(n+7)B
Remote station READY
Perform data (parameter, positioning data, etc.)
setting.
 
 
Fig. 3.1   I/O signal timings