Инструкции По Установке для Hussmann dbp-01

Скачать
Страница из 27
Rev. 0508 
9
Soap and hot water are not enough to kill this bacteria. A 
sanitizing  solution  must  be  included  with  each  cleaning 
process to eliminate this bacteria.
1.   Scrub thoroughly, cleaning all surfaces, with soap 
and hot water.
2.   Rinse with hot water, but do not flood.
3.   Apply the sanitizing solution according to the 
manufacturer’s directions.
4.   Rinse thoroughly.
5.   Dry completely before resuming operation.
                          
CLEANING PRECAUTIONS
When cleaning:
• Do not use high pressure water hoses
• Do not introduce water faster than waste outlet can drain
• NEVER ON A SELF CONTAINED UNIT WITH AN EVAPORATOR FAN
• NEVER USE A CLEANING OR SANITIZING SOLUTION THAT HAS AN OIL 
   BASE (these will dissolve the butyl sealants) or an AMMONIA BASE 
    (this will corrode the copper componets of the case)
TO PRESERVE THE ATTRACTIVE FINISH:
• DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY
• DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS  
   (these will mar the finish)
User Information (Cont'd)
Maintenance
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heaters
Thermostats, and Lights.
Replacing Fluorescent Lamps
Fluorescent  lamps  are  furnished  with  a  shatterproof 
protective coating. The same type of lamp with protective 
coating must be used if replaced.
This  lamp  has  been  treated  to  resist  breakage  and  must  be
replaced  with  a  similarly  treated  lamp  in  order  to  maintain
compliance with NSF Standards.
NSF CODE 4.28.1
Contact  HUSSMANN  Chino  for  replacement
1-800-395-9229  x  2131
Replacement Lamp Part List
Refrigerated Lamps
Lamp
Q150T3/CL
J0/30V150W/79
Our Part No.
15-03-1081
15-03-1141
voltage
10VAC
0VAC
Rated Life
1500 Hrs
1500 Hrs
Manufacturer General electric Ushio America, Inc.
Our Cost
$7.00
$.55
Telephone
1-800-554-4680
1-800-760-7446
1-800-37-0097
General Electric has many national distribution locations. 
Call for your closest location.
Ushio America Inc. is located at:
10550 Camden Drive.
Cypress, CA. 90630
T-5 Bulbs
Please note: T-5 lights must be turned off and on after bulb 
replacement.
Evaporator Fans
The evaporator fans are located at the center front of these 
merchandisers directly beneath the display pans. Should 
fans or blades need servicing, always replace fan blades 
with the raised embossed side of the blade TOWARD THE 
MOTOR.
Copper Coils
The copper coils used in Hussmann merchandisers may 
be repaired in the field. Materials are available from local 
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.