Инструкции По Установке для 3com S7906E

Скачать
Страница из 2621
 
1-9 
 
Smart Link Device Configuration Example 
Network requirements 
Create smart link group 1.  
The protected VLANs of smart link group 1 are mapped to MSTI 0 through 8.  
Configure GigabitEthernet 2/0/1 as the master port of the smart link group, and GigabitEthernet 
2/0/2 as the slave port.  
Configure VLAN 20 for flush update.  
Configure the collaboration between Smart Link and the CC function of CFD on GigabitEthernet 
2/0/1 and GIgabitEthernet 2/0/2. 
Configuration procedure 
<Sysname> system-view 
[Sysname] vlan 20 
[Sysname-vlan20] quit 
[Sysname] interface gigabitethernet 2/0/1 
[Sysname-GigabitEthernet2/0/1] undo stp enable 
[Sysname-GigabitEthernet2/0/1] port link-type trunk 
[Sysname-GigabitEthernet2/0/1] port trunk permit vlan 20 
[Sysname-GigabitEthernet2/0/1] quit 
[Sysname] interface gigabitethernet 2/0/2 
[Sysname-GigabitEthernet2/0/2] undo stp enable 
[Sysname-GigabitEthernet2/0/2] port link-type trunk 
[Sysname-GigabitEthernet2/0/2] port trunk permit vlan 20 
[Sysname-GigabitEthernet2/0/2] quit 
[Sysname] smart-link group 1 
[Sysname-smlk-group1] protected-vlan reference-instance 0 to 8 
[Sysname-smlk-group1] port gigabitethernet 2/0/1 master 
[Sysname-smlk-group1] port gigabitethernet 2/0/2 slave 
[Sysname-smlk-group1] flush enable control-vlan 20 
[Sysname-smlk-group1] quit 
[Sysname] interface gigabitethernet 2/0/1 
[Sysname-GigabitEthernet2/0/1] port smart-link group 1 track cfd cc 
[Sysname-GigabitEthernet2/0/1] quit 
[Sysname] interface gigabitethernet 2/0/2 
[Sysname-GigabitEthernet2/0/2] port smart-link group 1 track cfd cc 
Configuring an Associated Device 
Enabling the Receiving of Flush Messages 
You do not need to enable all ports on the associated devices to receive flush messages sent from the 
transmit control VLAN, only those on the master and slave links between the smart link device and the 
destination device.  
Follow these steps to enable the receiving of flush messages: