7 Robotic Assembly Replacement
Before You Begin
The model you are installing may vary slightly from the illustrations; however, the 
steps in the procedure are the same regardless of the model you are installing. If your 
assembly includes a T8 Torx L-key and screw, use them as noted.
Procedure Overview
This procedure involves the following steps:
1.
Assembling the materials you’ll need to complete the replacement
2.
Preparing the library prior to shutdown
3.
Removing the robotics assembly—a picker and its base—from the library
4.
Removing the old picker assembly from the old base
5.
Installing the new picker assembly on the new base
6.
Inserting the robotics assembly into the library
7.
Confirming operation of the new robotic assembly in the library
Assembling Tools and Materials
Assemble the following tools and materials 
required to complete this procedure:
• Your library key
• A #1 Phillips screwdriver 
(magnetized is recommended)
• A #2 Phillips screwdriver
• A 3/32 Allen wrench
• A small binder clip
• A new robotic assembly, P.N. 90959019 
(shown unpacked in Figure 7-5)
• A T8 Torx L-key and screw, included in 
your new robotic assembly
Caution:
When unpacking the new 
robotics assembly, note the 
packaging materials and 
method.
After you install the new 
assembly, package the old 
assembly using the same 
method and packaging. Return 
the properly packaged 
assembly to Spectra Logic for 
inspection.
Note that damage that results 
from incorrect packaging voids 
the warranty.