Release Notes for Cisco ONS 15454 SDH Release 4.0
OL-3487-01
Changes to the Release Notes
Changes to the Release Notes
This section documents supplemental changes that have been added to the Release Notes for Cisco ONS 
15454 SDH Release 4.0 
since the production of the Cisco ONS 15454 SDH System Software CD for 
Release 4.0.
The following changes have been added to the release notes for Release 4.0.
Changes to Caveats
The following caveat has been added to the release notes.
Caveats
Review the notes listed below before deploying the ONS 15454 SDH. Caveats with DDTS tracking 
numbers are known system limitations that are scheduled to be addressed in a subsequent release. 
Caveats without DDTS tracking numbers are provided to point out procedural or situational 
considerations when deploying the product.
TL1
DDTS # CSCsh41324
When running release 4.1.4, if a circuit is created within CTC and if that circuit is retrieved 
via TL1, all looks as expected. However, after the software is upgraded to release 6 and 
latter, the circuit retrive does not show the same value as was before. For example FAC-4-1 
changes to FAC-4-0. Workaround is to delete and recreate the circuit within CTC.
Hardware
DDTS # CSCdw92634 
SDH DS3-i and E3 electrical cards only support a VC4 J1 trace string setting for all VC4s together. You 
cannot set the J1 byte for individual VC4s. This issue is a limitation of hardware.    
Note
VC3 J1 strings can be set individually, but the optical cards cannot monitor the VC3 J1 string.