Справочник Пользователя для Pelco HK700

Скачать
Страница из 4
C2412M (11/99)
BK700 Series Blower Kit
HK700 Series Heater Kit
®
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1.
Installation and servicing should only be done by qualified service personnel and conform
to all local codes.
2.
Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P
enclosure, it is designed for indoor use only and it must not be installed where exposed to
rain and moisture.
3.
Only use replacement parts recommended by Pelco.
4.
After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
3500 Pelco Way
Clovis, CA 93612-5699
USA
In North America & Canada:
Tel (800) 289-9100
FAX (800) 289-9150
International Customers:
Tel +1 (559) 292-1981
FAX +1 (559) 348-1120
www.pelco.com
MODELS
Blower Kits
BK700
For use with E706 or E708 Series Enclosure, 120 VAC, 60 Hz, 4 watts,
10 cfm internal air circulation
BK700/220
Same as BK700 except 230 VAC, 50 Hz, 9 watts, 8 cfm internal air
circulation
BK700/24
Same as BK700 except 24 VAC, 3 watts, 19 cfm of internal air circulation
Heater Kits
HK706-1
Thermostatically controlled, 120 VAC, 80 watts, for E706 Series Enclosure
only. Activates ON at 40°F (4°C) and OFF at 60°F (16°C)
HK706-2
Same as HK706-1 except 24 VAC
HK706-3
Same as HK706-1 except 230 VAC
HK708/10-1
Thermostatically controlled, 120 VAC, 107 watts, for E708 Series
Enclosure only. Activates ON at 40°F (4°C) and OFF at 60°F (16°C)
HK708/10-2
Same as HK708/10-1 except 24 VAC, 66 watts
HK708/10-3
Same as HK708/10-1 except 230 VAC, 84 watts
INSTALLATION
CAUTION:  
When a single power source is used for both the camera and
accessories, the camera power consumption must be taken into consideration
when determining the wire gauge. However, the following chart does not
include camera power because of the many variations.
Model Number
Input Voltage
Power Consumption
Cable Size
Cable Distance
BK700
120 VAC
4 watts
22 AWG
10,651 feet
(3,246 m)
20 AWG
17,143 feet
(5,225 m)
18 AWG
27,108 feet
(8,262 m)
16 AWG
43,062 feet
(13,125 m)
BK700/24
24 VAC
3 watts
20 AWG
914 feet
(279 m)
18 AWG
1,446 feet
(441 m)
16 AWG
2,297 feet
(700 m)
14 AWG
3,650 feet
(1,113 m)
Table A.  Power Requirements and Recommended Cable Sizes
Continued on next page