Справочник Пользователя для Pelco HK700

Скачать
Страница из 4
E700 SLED MOUNTING BRACKET
BLOWER ASSEMBLY
PC BOARD (230 VAC ONLY)
Figure 1.  Blower Kit Installation
HEATER BRACKET 
ASSEMBLY
REAR PLATE
PC BOARD ASSEMBLY
CAMERA SLED
Heater Kit
If you are installing the heater kit in conjunc-
tion with a blower kit, skip this section and
refer to 
Blower and Heater Kits (Dual
Installation).
Perform the following steps to complete the
heater kit installation:
1.
Attach the PC board assembly onto the
brackets that are attached to the rear of
the camera sled (refer to Figure 3).
2.
Attach the heater assembly onto the
front of the camera sled (refer to
Figure 3).
3.
Route the wiring from the heater
assembly along the side of the camera
sled.
4.
Wire power to the PC board. Refer to
Figure 4 and Table A.
Figure 4.  Blower and Heater Kits Wiring Diagram (All Models)
Figure 3.  Heater Kit Installation
RED
BLK
BLK
BLK
BLK
BLK
FAN
24 VAC
FAN
110 VAC
FAN
230 VAC
PCB9000277ASSY
DIODE BRIDGE RECTIFIER
+
_
BUTT SPLICES PROVIDED
BUTT SPLICES PROVIDED
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
AC IN
AC IN
AC IN
BK700/24
BLOWER WIRING DIAGRAM
BK700
BLOWER WIRING DIAGRAM
BK700/220
BLOWER WIRING DIAGRAM
AC NEUT INPUT
AC HIGH INPUT
AC NEUT INPUT
AC HIGH INPUT
AC NEUT INPUT
AC HIGH INPUT
BUTT SPLICES PROVIDED
3K RESISTOR
Figure 2.  Blower Kit Wiring Diagram
AC HIGH
AC LOW
GROUND
(120 VAC, 50/60 HZ INPUT)
FAN
1
2
3
4
5
6
7
8
9
10
THERMOSTAT
CIRCUIT BOARD
TERMINAL BLOCK
1
2
3
4
5
6
7
8
9
10
THERMOSTAT
CIRCUIT BOARD
TERMINAL BLOCK
1
2
3
4
5
6
7
8
9
10
THERMOSTAT
CIRCUIT BOARD
TERMINAL BLOCK
AC HIGH
AC LOW
GROUND
(230 VAC, 50/60 HZ INPUT)
AC HIGH
AC LOW
GROUND
(24 VAC, 50/60 HZ INPUT)
RESISTOR
FAN
FAN
DIODE BRIDGE
HEATER
HEATER
WHITE
WHITE
WHITE
WHITE
HEATER
HEATER
WHITE
WHITE
WHITE
WHITE
HEATER
HEATER
WHITE
WHITE
WHITE
WHITE