Справочник Пользователя для Pelco HK700

Скачать
Страница из 4
Model Number
Imput Voltage
Power Consumption
Cable Size
Cable Distance
BK700/200
230 VAC
9 watts
20 AWG
25,609 feet
(7,805 m)
18 AWG
40,495 feet
(12,342 m)
16 AWG
64,328 feet
(19,606 m)
14 AWG
102,239 feet
(31,161 m)
HK706-1
120 VAC
80 watts
20 AWG
533 feet
(162 m)
18 AWG
857 feet
(261 m)
16 AWG
1,355 feet
(413 m)
14 AWG
2,153 feet
(656 m)
HK706-2
24 VAC
80 watts
20 AWG
34 feet
(10 m)
18 AWG
54 feet
(17 m)
16 AWG
86 feet
(26 m)
14 AWG
137 feet
(42 m)
HK706-3
230 VAC
80 watts
20 AWG
2,881 feet
(878 m)
18 AWG
4,556 feet
(1,389 m)
16 AWG
7,237 feet
(2,206 m)
14 AWG
11,502 feet
(3,506 m)
HK708/10-1
120 VAC
107 watts
22 AWG
398 feet
(121 m)
20 AWG
641 feet
(195 m)
18 AWG
1,013 feet
(3092 m)
16 AWG
1,6102 feet
(491 m)
HK708/10-2
24 VAC
66 watts
20 AWG
42 feet
(13 m)
18 AWG
66 feet
(20 m)
16 AWG
104 feet
(32 m)
14 AWG
166 feet
(51 m)
HK708/10-3
230 VAC
84 watts
20 AWG
2,744 feet
(836 m)
18 AWG
4,399 feet
(1,322 m)
16 AWG
6,8928 feet
(2,101 m)
14 AWG
10,954 feet
(3,339 m)
Combination of
120 VAC
84 watts
22 AWG
507 feet
(155 m)
BK700 &
20 AWG
816 feet
(249 m)
HK706-1
18 AWG
1,291 feet
(393 m)
16 AWG
2,051 feet
(625 m)
Combination of
24 VAC
83 watts
20 AWG
33 feet
(10 m)
BK700-24 &
18 AWG
52 feet
(16 m)
HK706-2
16 AWG
83 feet
(25 m)
14 AWG
132 feet
(40 m)
Combination of
230 VAC
89 watts
20 AWG
2,590 feet
(789 m)
BK700/220 &
18 AWG
4,095 feet
(1,248 m)
HK706-3
16 AWG
6,505 feet
(1,983 m)
14 AWG
10,339 feet
(3,151 m)
Combination of
120 VAC
111 watts
22 AWG
384 feet
(117 m)
BK700 &
20 AWG
618 feet
(188 m)
HK708/10-1
18 AWG
977 feet
(298 m)
16 AWG
1,552 feet
(473 m)
Combination of
24 VAC
69 watts
20 AWG
40 feet
(12 m)
BK700/24 &
18 AWG
63 feet
(19 m)
HK708/10-2
16 AWG
100 feet
(30 m)
14 AWG
159 feet
(48 m)
Combination of
230 VAC
93 watts
20 AWG
2,748 feet
 (755 m)
BK700/220 &
18 AWG
3,919 feet
 (1,194 m)
HK708/10-3
16 AWG
6,225 feet
 (1,897 m)
14 AWG
9,894 feet
 (3,016 m)
Blower Kit
If you are istalling the blower kit in conjunction with a heater kit, skip this section and refer to
Blower and Heater Kits (Dual Installation)
.
To install a blower kit, perform the following steps:
1.
Attach the blower assembly onto the brackets at the rear of the camera sled using the
hardware provided (see Figure 1).
 2.
Wire as shown in Figure 2. Refer to Table A for recommended cable sizes.
Table A.  Power Requirements and Recommended Cable Sizes (Continued)