RFI Grounding
The 
iQ  Series 
generator provides the operating power 
and power returns. Make sure the generator is grounded 
properly.
In addition to the safety considerations, proper grounding 
is essential for the effective suppression of RFI (Radio 
Frequency Interference). Every generator contains a 
RFI filter which blocks noise on the AC power line from 
entering the generator control circuitry. This filter also 
prevents ultrasonic RFI from being fed back into the AC 
power line. 
If you experience problems with RFI from the press, run 
an additional grounding wire from the press base ground-
ing stud to the nearest grounded metal pipe or equivalent 
earth ground by means of a ground clamp. Use at least 14 
AWG wire for the connection to the press base.
CAUTION
To minimize electrical noise 
and eliminate ground cur-
rents, ground the chassis 
as shown. Use a STAR con-
figuration (illustrated below). 
Do not DAISY CHAIN the 
grounds.
Earth
Ground
#14 Gauge
 
Stranded or
Solid Wire
Fixed Probe Mount
 or 2nd Chassis
Grounding Stud
 
3rd Chassis 
Grounding
Stud
 
Chassis Grounding
Stud
Recommended protective 
earth ground connection 
wire color: green or green 
with yellow stripe.