Справочник Пользователя для Dukane 403-575-00

Скачать
Страница из 136
 
Select Force as the type of trigger.
Then program the desired pounds of force.
Next, program Max Trigger Time. This provides a mea-
sure of safety insuring the welder will fault if for some 
reason the welder never achieves the programmed trigger 
force. See Figure 4-9.
NOTE
The example shown in Figure 4-9 
assumes trigger force for a part with 
four linear inches of weld would need 
between 32 - 42 lbs of trigger force
A 20 inch linear weld may require 
between 52 - 70 lbs. of trigger force. 
See Figure 4-10, Initial Trigger Force 
Settings. 
Figure 4-9
 
iQ Explorer, Process Settings > Trigger > Type > Force > Max Trigger Time
Servo Step 5 - Process Settings > Trigger > Type
Figure 4-10
 
Suggested Initial Trigger Force Setting
Page 46 
iQ  Series
 Ultrasonic Generator/Power Supply ES User’s Manual
Dukane Manual Part No. 403-575-00
Fo
rce (pounds)
Linear Weld Joint  (inches)
110
105 
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0         2         4         6         8         10       12        14       16       18       20       22       24       26       28       30       32       34       36
40
6.000
40