Step 16. Turn on gas supply and test for gas leaks using a gas leak test 
solution (see Test Procedure on Page 18 of the Installation and 
Operation Manual).
Step 17. Using a manometer, test the inlet and manifold gas pressure 
per instructions in the Installation and Operation Manual (Page 
18and as shown in the following 2 tables.  
Step 14. Reinstall the log set and glass door assembly.  See Page 12 
(Log Set Installation) and Page  25 (Door Assembly Installation) 
in the Installation and Operation Manual.
Step 15. Light the appliance per the lighting instructions label on appliance 
(located inside left door) or lighting instructions on Page 19 of 
the Installation and Operation Manual.  Inspect for proper pilot 
and burner flame appearances (see Figures 15 and 16 below).  
Also see Flame Color and Behavior and Inspect The Pilot System 
For Proper Flame on Page 20 of the Installation and Operation 
Manual.
Figure 16  - Burner Flame Appearance
No Blue Flame 
Center
Soot at 
Flame Tip
Dark Orange 
Flame
IMprOpErLy 
BurNING FLaME
Soot above 
Flame Tip
No Soot at 
Flame Tip
prOpErLy
BurNING FLaME
Semi-Transparent 
yellow Flame 
Blue Flame 
Center
ports on pan 
Burner assembly
Figure 15 - Proper Pilot Flame Appearance
Safety Label
Step 15.Remove the sticker covering the model on the label so that it 
reads  “Epic NG40” if orifice #31 is installed. Use the sticker 
“Epic NG33” to cover “Epic NG40” on the label if orifice #36 
is installed.  The label is located on  the inside of the left hand 
door (see Figure 14).
Figure 13
Figure 14
Step 14. Before you secure the burner with screws, double check that 
the orifice is positioned into the burner neck by feeling around 
the back of the burner (see Figure 13). Then, lower the burner 
so it sits flush on the burner supports and replace the 2 screws 
removed in step 6 (see Figure 13).
reach behind burner and feel orifice to 
ensure it is centered in the burner neck
Lower burner flush and reinstall 
screws (indicated by arrows)
Burner
Burner
Inlet Gas Supply pressure 
Fuel #
Minimum
Maximum
Desired
Nat.
Gas
5" wC/po. C.E
(1.24 kpa)
10.5" wC/po. C.E
(2.61 kpa)
7" wC/po. C.E
(1.74 kpa)
Manifold Gas Supply pressure
Fuel #
Low
high
Natural
Gas
(Lo) 1.7" wC/po. C.E
(0.42 kpa)
(hi) 3.5" wC/po. C.E
(0.87 kpa)
4
printed in u.S.a. © 2007 Lennox hearth products
p/N  775,235M  rEv. C  03/2008
Lennox reserves the right to make changes at any time, without notice, in design, 
materials, specifications, prices and also to discontinue colors, styles and products. 
Consult your local distributor for fireplace code information.