4.4.3  Management Interface 
Click 
Management Interface
 in the system menu (left side of screen) to view and edit 
the IP address and DHCP settings. 
 
Figure 31: Web: Configuration - Management Interface Screen 
IP Parameters 
Obtain IP Parameters from DHCP Server: Select this option to have the base station 
obtain its IP address from a DHCP server. 
Use the following IP Parameters: Manually enter the following IP parameters: 
IP Address: Enter the static base station network IP address. 
Subnet Mask: Enter the base station subnet address mask. 
Default Gateway: Enter the IP address of the default gateway on the local Ethernet 
segment. 
Time Server (SNTP): Enter the IP address of the SNTP server. 
Use the following checklist to ensure correct display options: 
1.  Time server must be compatible with SNTP (RFC-2030) 
2.  Ensure the time zone is correct for your area. 
3.  If you are in an area that observes daylight savings time, check the box. 
Time Zone: Enter the time offset from GMT (hours:minutes). 
Daylight Savings: Check   to enable automatic time change for daylight savings. 
Syslog Server: Enter the IP address of the Syslog server to enable this feature. 
Refresh: Click  
Refresh Time  
to poll the time server for the current time.