Section 3 Engineering Guidelines
612806420L1-1A
Copyright © 2005 ADTRAN, Inc.
27
Front Panel LEDs
With the TRACER powered-on, the front panel LEDs provide visual information about the status of the
system. Table 2 provides detailed information about the LEDs.
system. Table 2 provides detailed information about the LEDs.
AUX RS232 Interface (RJ-45)
The
AUX RS232
interface provides a female RJ-45 terminal connection (wired as a DCE interface), which
is used for a 9600 bps point-to-point connection between the local and remote systems (over the RF link).
Table 3 shows the pinout.
Table 3 shows the pinout.
Table 2. TRACER 6420 LEDs
For these LEDs...
This color light...
Indicates that...
PWR
Green (solid)
the TRACER is connected to a power source.
Off
the TRACER is not currently powered up.
TST
Amber (flashes once)
power-up self-test is in progress. If the LED continuously flashes
or remains on (solid) after 10 seconds, the unit has failed
self-test.
or remains on (solid) after 10 seconds, the unit has failed
self-test.
STATUS
MOD1 and MOD2
Green
the module is installed and functioning properly.
Red (solid)
a port on the installed module is currently in alarm.
Off
no module occupies the slot.
PLAN A
Green (solid)
the TRACER is transmitting on Frequency Plan A.
Off
the TRACER is not transmitting on Frequency Plan A.
PLAN B
Green (solid)
the TRACER is transmitting on Frequency Plan B.
Off
the TRACER is not transmitting on Frequency Plan B.
RF LO
Red (solid)
the RSSI level is below suggested minimum threshold
(approximately 10 dBm above the minimum receive sensitivity).
(approximately 10 dBm above the minimum receive sensitivity).
RF DWN
Red (solid)
there is a communication problem between the local and remote
TRACERs.
TRACERs.
Table 3. AUX RS232 Pinout
Pin
Name
Source
Description
1
GND
Common
Signal ground
2
RTS
Attached Equipment
Request to send (unused)
3
TXDATA
Attached Equipment
Transmit data (from attached equipment)
4
DSR
TRACER
Data set ready
5
RXDATA
TRACER
Received data (to attached equipment)
6
CTS
TRACER
Clear to send
7
DTR
Attached Equipment
Data terminal ready (unused)
8
CD
TRACER
Carrier detect