Справочник Пользователя для Rohde & Schwarz Inc SLV8000

Скачать
Страница из 328
Chapter 5
Operating
2100.4400.32
- 5.66 -
E-2
6.2
TV Settings > RF Out > Synthesizer
a) When the time scheduler is enabled, the appropriate setting from the Time Scheduler Configuration menu 
has priority.
Display
Symbol
Description
Actual Power 
Status
OK
Power display is valid
W
Power display is invalid
The internal power meter of an amplifier is overloaded; the actual 
output power may be above the displayed power.
RF Fail
- OFF -
RF power at the output of the output stage OK or transmitter 
switched off
F
RF power is below the threshold specified under RF Fail Limit
Amplifier
OK
No warning at the output stage
W
Output stage signals a sum warning
Display
Description
Actual Power
Present forward power of the transmitter
Setting item
Description
Frequency 
 a)
a) When the time scheduler is enabled, the appropriate setting from the Time Scheduler Configuration menu 
has priority.
Used to set the transmission frequency
Frequency Offset
If a frequency offset exists, it is added directly to the transmission fre-
quency (DVB only)
The frequency offset transferred in the MIP is addressed to a specific 
transmitter in the network and is only evaluated if the Tx address set in 
the TV Settings > DVB > Common menu window identifies the correct 
receiver. Additionally, to allow display and activation, Tx Automatic must 
be activated under TV Settings > DVB > Common.