Справочник Пользователя для Movea Inc MPOD3

Скачать
Страница из 18
 
 
 
 
 
 
12 
o
 
Keys : 15 cm 
o
 
While using the MPOD for measurement or calibration (see further below), see to it 
that there isn’t any object likely to disturb measurements (ferrous objects, watches, 
mobile phone…) 
o
 
 MPOD should be used far from motorized chairs or beds. 
o
 
Only  small  magnets  are  accepted  in  the  same  room  (i.e.  whiteboard  magnet),  but 
must be kept far from the MPOD (>50 cm), as they might cause a serious decrease in 
the systems accuracy. 
o
 
DO  NOT  TO  PUT  THE  MPOD  IN  CONTACT  WITH  A  MAGNET  AS  IT  WILL  MAKE  IT 
PERMANANTLY USELESS. 
o
 
The presence of strong magnetic field generating machines (like MRI) is not adapted 
to the use of MPOD™.  
2.
 
CHARACTERISTICS AND ENVIRONMENTAL CONDITIONS 
Usage conditions 
 
Temperature 
Stable between 0°C and 35°C 
Maximum dynamic acceleration measured 
-8g à 8g 
When  not  using  gyroscopes,  orientation  measures  are  valid  for  static  and  quasi  static 
positions. When using gyroscopes body motion must be limited to sensors limit. 
 
 
The  measured  orientation  parameter  is  valid  in  a  uniform  or  quasi  uniform  magnetic  field  between    -6 
gauss and +6 gauss
1
 
 
Maximum Shock resistance 
4600 g for a time of 0,5 ms 
 MPOD should not be thrown away violently. 
It  is  however  resistant  to  shocks  in  normal 
conditions of use. 
Magnetic field survivability 
10 000 Gauss 
Maximum  rate  of  magnetic  field  tolerated  before  miss-
calibration  
20 Gauss 
 
 
 
 
Packaging and transport conditions
 
Temperature 
Between  -20°C  and  35°C  (For  6  month 
maximum) 
45°C (For 1 month maximum) 
Shock resistance 
4600 g for a time of 0,5 ms 
Magnetic field survivability 
10 000 Gauss 
Maximum  rate  of  magnetic  field  tolerated  before  miss-
calibration 
20 Gauss 
 
 
Storage conditions 
 
                                                            
1
 MotionDevTool v2.0.4 software automatically checks if this condition is verified during recording of the 
movement signature. An alarm is emitted in case of magnetic disturbance. If there is no alarm, the user is 
under desired conditions.