3.6.8.1.1.2 Notch Monitor Data Screen
The Notch Monitor Screen is shown in 
. This screen displays the Notch Monitor data from the associated 
Monitor.  The  monitor  measures  the  signal  from  the  Field  Monitor  for  “notches”  in  the  detected  signal.  A  notch 
indicates a fault in one or more transmitting antennas, feed cables or commutator switch channels. When a failure 
occurs  in  one  of  these  channels  there  is  a  lack  of  signal  and  therefore  a  notch  in  the  detected  signal  pattern.  The 
1150A DVOR is a double sideband configuration and therefore there are four sideband antennas on at any one time. 
Therefore the notch will not fall to zero but since three other antennas are contributing to the signal only a reduction 
in signal can be expected. 
 
The Record baseline button is used when the technician is confidant that the DVOR is operating properly, such as 
following a flight inspection of the facility. When the Record Baseline button is pressed, the current data is copied 
into  memory  as  the  “Baseline”  Data  and  then  used  as  the  reference.  If  the  Sideband  power  is  varied,  then  a  new 
baseline  will  be  required.  When  the  measured  signal  differs  from  the  Baseline  by  more  than  the  Notch  Monitor 
tolerance set in the Monitor Alarm Limits screen, the alarm (red) or alert (yellow) indication is generated, depending 
on if the Notch Monitor is configured as a Primary or Secondary Alarm. 
 
The tolerance for notch monitoring should be set to approximately 20% in the Monitor Alarm Limit screen, but the 
technician can adjust this tolerance as needed for more or less sensitivity. Note that when one antenna fails there will 
typically  be  an  out-of-tolerance  indication  for  one  to  four  of  the  possible  radiating  antennas.  When  an  out  of 
tolerance condition exists, the Sideband VSWR data screen should be reviewed as well. If there is an indication of 
Sideband VSWR alarm, investigate the VSWR alarm indication first.  
 
Figure 3-32  Notch Monitor 1 & 2 Data