Справочник Пользователя для Selex Sistemi Integrati Inc. VOR2

Скачать
Страница из 254
Model 1150A DVOR 
 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
3-37
3.6.8.1.1.3 Sideband Antenna VSWR Screen
The Sideband Antenna VSWR screen is shown in 
. This screen displays the current Sideband Antenna 
VSWR data for the associated monitor. Note that Sideband VSWR Data is only displayed for the monitor associated 
with the on-air transmitter. 
 
When the measured signal exceeds the Sideband Antenna VSWR tolerance set in the Monitor Alarm Limits screen, 
the alarm (red) or alert (yellow) indication is generated, depending on if the Sideband Antenna VSWR is configured 
as a Primary or Secondary Alarm. If configured as a Primary Alarm, and the number of antennas in alarm exceeds 
the “Number of Antennas in Alarm” then the DVOR will shut down after the alarm delay expires.  
 
Figure 3-33  Sideband Antenna VSWR Data Screen