Справочник Пользователя для Microwave Radio Communications LLC STATXU064T1CK

Скачать
Страница из 98
 Routine Operation
3-33
STRATA TX Operator’s Guide/Tech Ref Manual
9.
Press the control switch for one second to place the 
TX System in the transmit mode, as required. 
3.6.4
Controlling TCU to TXU DC Power on Coax 
If your STRATA TX System requires the TXU and TCU to be 
mounted in separate locations, MRC recommends powering the 
TCU via the coaxial cable from the TXU. 
Note
When the TCU and TXU are mounted in separate 
locations, it is recommended that DC input power 
be connected to the TXU. 
Since either unit may be powered from the other 
unit via DC power superimposed on the coaxial 
cable between the units, DC input power may 
therefore be applied to either the TXU or the TCU.
If your TXU and TCU configurations contain DC ON COAX 
switches mounted on the units, these switches must be set to 
ON in addition to controlling DC power superimposed on the 
coaxial cable from the TXU to the TCU or from the TCU to the 
TXU. 
To apply DC power from the TXU to the TCU superimposed on 
the coaxial cable between the two units, perform the following 
steps.
Notes
This procedure must only be performed on 
STRATA TX Systems where the TXU and TCU are 
physically mounted in separate locations.
This procedure may be performed using either the 
TXU or TCU control switch and display.
Apply DC Power on Coax  
1.
Verify the STRATA TX System is connected and 
powered up. 
2.
Observe the Main screen is displayed.  
Figure 3-32: Main Screen 
Note
If your TCU does not contain a DC ON COAX 
switch, go to step 4.
3.
Turn the recessed DC ON COAX switch on the front 
panel of the TCU until the screw slot points to OFF.
4.
Turn the recessed DC ON COAX switch on the front 
panel of the TXU until the screw slot points to OFF.
5.
Turn the control switch ccw until the display reads 75 
Ohm Coax
.
 
.
Preset 3  
 .   W