Справочник Пользователя для UTC Fire & Security B.V. NX1700E

Скачать
Страница из 16
NX-1700E Card Reader
5
I.
GENERAL DESCRIPTION
The NetworX NX-1700E is a proximity card reader / door control module used to expand the capabilities
of the NetworX control panels.
Microprocessor-controlled
Includes one (1) low current trigger output, which can be used to control a door strike relay
Up to 15 card readers can be connected to the NetworX control panel
Can be programmed to control access in any or all partitions
LEDs can be programmed to follow the output and/or the armed or ready status of the system
Has an optional optical tamper switch
II.
WIRING DESCRIPTION
DESCRIPTION
GREEN
(DATA)
Connect to the control panel DATA terminal. This wire is the data-signaling terminal to all
the devices on the buss.
BLACK
(COM)
Connect to the control panel COMMON terminal. Supplies the common side of the
power to the card reader module.
RED
(POS)
Connect to control panel AUX POWER + terminal. Supplies power to the card reader
module.
WHITE
(EGRESS)
This is an optional (exit) EGRESS input. To use this feature, connect the normally open
egress switch between this terminal and COM. If this feature is not used, there is no
need to connect this wire.
BLUE
(OUTPUT)
This is an optional open-collector (negative trigger) OUTPUT. To use this feature,
connect the coil contacts of a relay between this terminal and AUX POWER +. Absolute
maximum 14 volts @ 25mA.
This is a low current output and must not be used to directly energize high
current door openers.
III.
INSTALLATION
To install the card reader, simply wire it into the system. Refer to the above wiring table for details.
IV.
ENROLLING
The NetworX control panels have the ability to automatically find and store in memory the presence of all
keypads, zone expanders, wireless receivers, output modules, and any other device on the keypad buss.
This allows these devices to be supervised by the control panel. To enroll the devices, enter the
Program Mode using the procedure outlined in the control panel Installation Manual. When the Program
Mode is exited, the NX-8 control will automatically enroll the devices. The enrolling process takes about
12 seconds, during which time the Service LED will illuminate. User codes will not be accepted during
the enrolling process. Once a module is enrolled, if it is not detected by the control, the Service LED will
illuminate.