Справочник Пользователя для Checkpoint Systems Inc. EVOLVEF10

Скачать
Страница из 71
F10 Installation Manual 
                         Rev. *60          
 
17 of 71
 
Parts 
Quantity will vary according to system type.    
  18 AWG 2-conductor (STP) Power 
  22 AWG 4-conductor (STP) (5594) Sync 
  PVC cement  
  *DekDuct (wire chase) 
  *Wiremold (1500 or 2600 series) 
  *Wiremold anchor bolts  
  Note: *Wire routing methods will vary by installation. 
  Note: Complete parts lists with OEM Part Numbers are included in 
. 
Installation Outline 
Follow this sequence to successfully install the components and validate system operation:  
1.  Determine optimal antenna placement:  
a.  Perform a site survey now, or 
b.  Use the results of a previous survey.  
2.  Determine power supply requirements and the ideal location for system electronics.  
3.  Physically install the antenna(s).  
4.  Route/connect the antenna (coax cable) and applicable wiring (sync, alarm, power). 
5.  Install the peripherals and wire the device(s) to the electronics enclosure.  
6.  Configure the system using DMS.  
7.  Perform system specific tuning (test jump positions).  
Antenna Installation 
Antenna installation and tuning is performed by trained Checkpoint personnel. You have already 
determined the system model(s) and number of assemblies for install, or you recently received this 
key information from a prior survey. If you are unsure of any specifics, contact Checkpoint Project 
Management.
 
Install the antenna(s) in the proper location(s) discovered during the site survey.  
During Construction 
If the floor has not been poured yet, a pre-fabricated trough can be constructed. Refer to Figures 
3.3 and 3.4. In the event of a new construction, please convey the following information to the site 
contractors (construction team’s foreman) or the manager responsible for pouring the concrete:  
•  Location where antenna (s) will be placed; define a reference point (such as a door frame). 
•  The exact dimensions of antenna(s); provide the appropriate Floor Cut diagram(s).  
•  The depth, length and pathway of the 1/2” ENT Tubing (conduit), if installed ahead of 
time; depth of the trench for routing the cable is 3.8cm [1.5in] deep.   
After Construction  
For sites where floor cuts must be made, convey the following instructions to the installing 
technician. Communicate all known specifics to the installer, referring to the diagram(s). Be sure 
to convey plans and instructions for the correct system type. Only provide the floor layout(s) for 
required antenna configuration(s).  If using a chisel, rough / uneven floor cuts may occur.  Flatten 
the bottom surface on which the antenna rests with either leveling sand or a layer of concrete fill.