Справочник Пользователя для CONTELA INC. CHAMOMILE-A1
Installation manual for LoRa Gateway
10(12)
Connect the AC power to the LoRa Gateway through an external power distribution box.
The AC power cable is not provided separately. Only the connector that is connected to
the LoRa Gateway is provided, and connect the AC power cable by assembling the
waterproof connector that comes with LoRa Gateway.
The figure below shows the pin map of the AC input connector.
When working on AC input cable in the field, make sure to use it according to the pin map
shown below.
Figure 1.20-7 AC Power connector Pin map 4
5
The AC power connector specification conforms to the MS3106A-10SL-3 (MIL-C-5015)
And the connector connected to the cable is MS3106A-10SL-3 (MIL-C-5015).
When installing, prepare the MS3106A-10SL-3 (MIL-C-5015) (supplied) and make the cable
according to the pin map above.
After connecting the power cable, be sure to finish using a waterproof shrink tube to make it
waterproof and fix the cable to prevent it from being shaken by wind and vibration.
D. Grounding
Connect the ground wire through the ground terminal located on the right side (or left side)
of the enclosure.
A : AC_H
B : AC_N
C : GND
When connecting the power connector, make sure
that it is aligned with the erroneous insertion
protrusion, and be careful not to forcibly force the
connector or damage the connector.
connector or damage the connector.
Cautions