Справочник Пользователя для CONTELA INC. CHAMOMILE-A1

Скачать
Страница из 12
 
   
Installation manual for LoRa Gateway 
 
10(12) 
 
 
 
 
 
Connect the AC power to the LoRa Gateway through an external power distribution box.   
The  AC  power  cable  is  not  provided  separately.  Only  the  connector  that  is  connected  to 
the  LoRa  Gateway  is  provided,  and  connect  the  AC  power  cable  by  assembling  the 
waterproof connector that comes with LoRa Gateway. 
The figure below shows the pin map of the AC input connector. 
When working on AC input cable in the field, make sure to use it according to the pin map 
shown below. 
 
 
Figure 1.20-7 AC Power connector Pin map 4 
The AC power connector specification conforms to the MS3106A-10SL-3 (MIL-C-5015) 
And the connector connected to the cable is MS3106A-10SL-3 (MIL-C-5015). 
When installing, prepare the MS3106A-10SL-3 (MIL-C-5015) (supplied) and make the cable 
according to the pin map above. 
After connecting the power cable, be sure to finish using a waterproof shrink tube to make it 
waterproof and fix the cable to prevent it from being shaken by wind and vibration. 
 
 
 
 
 
 
 
 
 
 
D.  Grounding   
Connect the ground wire through the ground terminal located on the right side (or left side) 
of the enclosure. 
A : AC_H
B : AC_N
C : GND
When connecting the power connector, make sure 
that  it  is  aligned  with  the  erroneous  insertion 
protrusion, and be careful not to forcibly force the 
connector or damage the connector.
 
Cautions