8(12) 
 
 
 
 
 
is off), then apply power. (It takes about 20 ~ 30 seconds) 
(2) In case the red LED flashes repeatedly 
  Through  G-EMS,  check  the  IP  address  of  Network  Server  is  registered  in  LoRa 
Gateway. 
  Check  if  the  LoRa  gateway  is  registered  as  a  LoRa  gateway  that  can  be 
interworked to the Network Server. 
  If the current state continues after checking all above, check with the local NOC 
for the circuit configuration status. 
(3) In case the orange LED flashes repeatedly 
  Check if MMC command execution from G-EMS to LoRa Gateway is working. 
  In case MMC command from G-EMS is executed 
  Check if the G-EMS address registered in LoRa Gateway is correct.   
  Check if the Gateway’s request is processed normally on the G-EMS. 
  In case MMC command from G-EMS is not executed 
  Check the configuration of the line to make sure that there is no problem in 
network connection with G-EMS. 
 
 
 
1.2 Hardware Installation 
 
  Check lists for LoRa Gateway installation     
A.  Check the installation materials of LoRa Gateway   
  Check the contents of LoRa Gateway (AC input cable connector etc.) 
  Identification of facility materials (main installation bolt/nut, facility structure, etc.) 
B.  Check the external condition of LoRa Gateway before installation. 
  Make sure that the tightening screws of the LoRa Gateway are tightened and there is no 
problem with the waterproof structure. 
  Make sure that there is no apparent problem during the movement of each external port. 
C.  Check the installation direction of the LoRa Gateway. (Ports are always downward) 
  LoRa  Gateway  should  be  installed  in  a  position  where  the  upper  side  of  the  LoRa 
Gateway  is  open  to  see  the  sky  so  that  the  GPS  antenna  can  receive  the  satellite 
signals smoothly with the built-in GPS antenna. 
 
  Installation of LoRa Gateway 
Check that all the installation materials of LoRa Gateway are prepared. 
The following figure is an example of installing a pole, and it can be installed using a U-bolt 
(or pole mounting device, pole fixing band, etc.) as shown.