Installation manual for LoRa Gateway 
 
9(12) 
 
 
 
 
 
 
 
Figure 1.20 Example of pole installation for LoRa Gateway 2 
 
Once LoRa Gateway is installed, proceed with the RF service antenna connection, Backhaul 
connection, AC power connection and grounding work. 
 
 
 
 
 
A.  RF service antenna connection 
The  RF  service  antenna  connection  connector  uses  N-type  Reverse  (N-50Ω)  connector. 
After  connecting  the  antenna  cable,  finish  it  with  a  waterproof  shrink  tube  to  make  it 
waterproof. Fix the cables so that they do not shake in vibration or wind. 
 
B.  Backhaul Connection 
RJ45  connector  is  used  for  backhaul  connector,  and  Cable  grand  (DAM25,  Dong-A)  is 
used  for  connector  external  waterproof  connector.  The  Ethernet  cable  for  Backhaul  is 
constructed  by  connecting  method  that  can  be  waterproofed  by  using  corrugated  pipe 
fitting to the cable grand.   
After  connection,  waterproof  finishing  is  done  to  prevent  moisture  from  entering  into  the 
enclosure  by  using  waterproof  shrink  tube or  waterproof  silicone.  Fix  the  cable  so  that  it 
does not shake with vibration or wind. 
 
C.  AC power connection 
Be  careful  not  to  install  this  LoRa  Gateway  inside  the 
building because it is a GPS receiver embedded. 
 
Cautions