Справочник Пользователя для Hitachi RAC-25FXA RAC25FXA

Модели
RAC25FXA
Скачать
Страница из 706
 
10-4
 
 
 
1.  Drill holes on wall 
2.  Push plug into holes 
 
 
 
Wall Penetration and Installation of Protection 
Pipe 
• 
Drill a 65mm hole on wall which is slightly tilted 
towards the outdoor side. Drill the wall at a small 
angle 
• 
Cut the protection pipe according to the wall 
thickness 
• 
Empty gap in the sleeve of protection pipe 
should be completely sealed with putty to avoid 
dripping of rain water into the room.  
 
 
 WARNING  
• 
Be sure that the wire is not in contact with any metal 
in the wall. Please use the protection pipe as wire 
passing through the hollow part of the wall so as to 
prevent the possibility of damaged by mouse. 
Unless it seals completely, any air with high humidity 
flows from outdoor and dew may drop. 
Installation of the Indoor Unit 
 
Models: Wall type 
Maximum 
piping 
length (m) 
Minimum 
piping 
length (m) 
Maximum 
height (m) 
RAK-18PSA 
20 
10 
RAK-25PSA 
20 
10 
RAK-35PSA 
20 
10 
RAK-18PSAN 
20 
10 
RAK-25PSAN 
20 
10 
RAK-35PSAN 
20 
10 
RAK-18PSPA 
20 
10 
RAK-25PSPA 
20 
10 
RAK-35PSPA 
20 
10 
RAK-18QXA 
Refer to 
Outdoor 
Refer to 
Outdoor 
RAK-25QXA 
RAK-35QXA 
RAK-50QXA 
RAK-18QPA 
RAK-25QPA 
RAK-35QPA 
RAK-50QPA 
RAK-25PXA 
20 
10 
RAK-35PXA 
20 
10 
RAK-50PXA 
30 
10 
RAK-18PPA 
20 
10 
RAK-25PPA 
20 
10 
RAK-35PPA 
20 
10 
RAK-50PPA 
20 
10 
RAK-60PPA 
30 
20 
RAK-70PPA 
30 
20 
RAK-18PEA 
20 
10 
RAK-25PEA 
20 
10 
RAK-35PEA 
20 
10 
RAK-50PEA 
20 
10 
Screw 
20mm 
Plug 
Wall 
φ4.
4m
m
 
Remote 
control 
Holder 
Outdoor 
Indoor 
Seal with 
putty 
2~5mm 
Seal with 
putty 
Protection 
pipe 
Sleeve of 
protection 
pipe 
Be sure to 
completely 
seal any 
gap with 
putty 
Above 50mm 
Above 100mm 
A
b
o
ve 300
m
m
 
Above 
100mm 
The indoor piping should be 
insulated with the enclosed 
insulation pipe. (If the insulator 
is insufficient, please use 
commercial products 
M
us
not
 be
n
d
 
A
b
o
ve 
0.
45m
 
M
ax
im
um
 pip
e le
ngt
h
 
M
inim
um
 p
ipe
 le
ngt
h
 5
m
 
• 
The difference in height 
between the indoor and 
outdoor unit should be kept. 
• 
The connecting pipe, no matter 
big or small, should all be 
insulated with insulation pipe 
and then wrapped with vinyl 
tape. (The insulator will 
deteriorate if it is not wrapped 
with tape). 
The connection of 
insulated drain hose 
Please use insulated drain 
hose for the indoor piping 
(commercial product) 
Inner diameter φ16mm 
WALL 
2,300mm or more