10-5 
 
 
Vertically Downward Piping 
    Preparation 
• 
Connect the connecting cord 
• 
Pull out the pipe, connecting cord and drain hose. 
 
    Installation 
• 
The upper part of the Indoor  unit is hung on the 
hanger 
• 
The projection at the lower part of the Indoor unit 
is hooked onto the hanger. 
 
 CAUTION  
Please pull the lower part of the indoor unit outwards to 
check if the unit is hooked onto the hanger. Improper 
installation may cause vibration and noise. 
 
How to remove indoor unit 
• 
Push up the (PUSH) sections at the bottom of 
the indoor unit and pull the bottom plate towards 
you. Then the claws are released from the 
stationary plate. The (Push) sections are 
indicated by 2 arrows in figure. 
 
 
 
Horizontal Piping 
    Preparation 
Change of Drain Hose and Installation Procedures 
• 
Exchange the location of drain hose and drain 
cap during horizontal piping as shown in figure 
below. Be sure to plug in the drain hose until the 
insulation material folds upon itself. 
Please use pliers 
to pull out the drain 
cap. 
 
 
Condensed water may leak out if not inserted 
 CAUTION  
• 
Condensed water may leak out if not inserted 
properly. 
 
Horizontal & Downward Piping-Making 
Openings 
• 
During horizontal or 
downward piping, use a 
knife to cut openings as 
shown in figure. Then 
remove the sharp edges 
of openings with a file. 
 
• 
Turn the piping while holding down the lower 
portion of pipe-support by hand 
 
Installation of Refrigerating Pipes after 
Connection 
• 
The refrigerating pipes should be adjusted to fit into 
the hole on the wall and then ready for further 
connection. 
• 
The terminals of 2 connected pipes must be covered 
with insulator used for terminal connection. Then the 
pipes are wrapped with insulation. 
• 
Connect the connecting cord after removing 
electrical cover. (Refer to Chapter13 Electrical 
Wiring) 
 
• 
After adjustment, fit the connecting cord and pipes 
into the space available under the indoor unit. Use 
holder to hold them tight 
• 
Holder can be attached at the either of 2 places. 
Please select the easier position. 
  
Connecting cords, 
pipe and drain 
hose must be tied 
together with Vinyl 
tape 
Hanger 
Lift the body 
of the unit 
upwards and 
then force it 
downwards
Refrigerating 
pipe 
Hanger 
Connecting 
cord 
Protection 
pipe Drain Hose 
Hook 
Projection 
Drain cap  Drain hose 
Drain cap 
Drain hose 
Please 
insert until 
here 
Please 
insert until 
here 
Opening 
Drain hose 
Pipe 
Connecting cord 
Temporary stand 
[Push] marks position 
Pipe up the pipe 
after bending 
downward 
Pipe 
support