Техническая Спецификация для Conrad Energy Rechargeable AAA Battery x4 pc(s) NiZn 1.6V 4AAA900mWh1.6V
Модели
4AAA900mWh1.6V
Conrad Electronic SE · Klaus-Conrad-Str.1 · 92240 Hirschau
H
D
D
1
H
1
6 The outer case of battery , after tin-plated processing, the place is a little soft . For example, in
the battery use process, it is normal that the battery shell base presents the scratch. The
determination standard should be taken the bilateral consultation as a standard.
determination standard should be taken the bilateral consultation as a standard.
3 Measurement & Dimensions
to see the drawing:
D
≤10.5 mm
H
≤45.0 mm
4. TEST
4.1 Test conditions:
4.1.1 The battery to be tested is the product within one month after being received by customer.
4.1.2 Ambient conditions:
Temperature +20 ±5
Humidity +65%±20%
Humidity +65%±20%
4.2 Testing Tools
4.2.1 Voltage meter:
0.5 level or higher as required in IEC51/IEC485. Internal impedance exceeds 10KΩ/V.
4.2.2 Current meter:
0.5 level or higher as required in IEC51/IEC485. Internal impedance should be less than
0.01Ω/V(including wires).
0.01Ω/V(including wires).
4.2.3. Micrometer caliper:
With precision of 0.02mm.
4.2.4. Internal impedance meter:
Alternating current of 1000HZ, connector measuring equipment with sin wave of 4.
4.2.5: Impedance loaded meter:
Value of impedance is with +5% error allowed (including external wires).
4.3 Test methods and benchmarks
Items Test
Methods
Benchmarks
1 Appearance:
eyeballing
batteries shall be free from any stains;
scratches or deformations, which may
reduce the commercial value when
visually inspected
reduce the commercial value when
visually inspected
2 Size:
caliper measurement
The size shall comply with the
specified size as the attached drawing
3 Insulate
impedance
impedance
measured with a Megger overpack
and battery electrode between the
degree of insulation
degree of insulation
outer sleeve shall exceed 10 MΩ
4 Weight
using disk-scale measurement
approximate 11.0 g