Техническая Спецификация для Conrad Energy Rechargeable AAA Battery x4 pc(s) NiZn 1.6V 4AAA900mWh1.6V

Модели
4AAA900mWh1.6V
Скачать
Страница из 7
 
Conrad Electronic SE · Klaus-Conrad-Str.1 · 92240 Hirschau
 
H
D
D
1
H
1
6 The outer case of battery , after tin-plated processing, the place is a little soft . For example, in 
the battery use process,  it is normal that the battery shell base presents the scratch.  The 
determination standard should be taken the bilateral consultation as a standard. 
 
 
3 Measurement & Dimensions 
to see the drawing: 
 
≤10.5 mm 
≤45.0 mm 
 
 
 
 
4. TEST  
4.1 Test conditions: 
  4.1.1  The battery to be tested is the product within one month after being received by customer.  
4.1.2  Ambient conditions: 
                   Temperature                                +20 ±5  
                    Humidity                                     +65%±20% 
4.2 Testing Tools  
4.2.1 Voltage meter:  
0.5 level or higher as required in IEC51/IEC485. Internal impedance exceeds 10KΩ/V. 
4.2.2 Current meter:  
0.5 level or higher as required in IEC51/IEC485. Internal impedance should be less than 
0.01Ω/V(including wires). 
4.2.3. Micrometer caliper:  
With precision of 0.02mm. 
4.2.4. Internal impedance meter:  
Alternating current of 1000HZ, connector measuring equipment with sin wave of 4. 
4.2.5: Impedance loaded meter:  
Value of impedance is with +5% error allowed (including external wires). 
 
4.3 Test methods and benchmarks  
Items Test 
Methods 
Benchmarks 
1 Appearance: 
—
  eyeballing 
—
  batteries shall be free from any stains; 
scratches or deformations, which may 
reduce the commercial value when 
visually inspected 
2 Size: 
—
  caliper measurement  
—
  The size shall comply with the 
specified size as the attached drawing  
3 Insulate 
impedance 
—
  measured with a Megger  overpack 
and battery electrode between the 
degree of insulation  
—
  outer sleeve shall exceed   10  MΩ  
4 Weight 
—
  using disk-scale measurement  
—
  approximate  11.0  g