Техническая Спецификация для Conrad Energy Rechargeable AAA Battery x4 pc(s) NiZn 1.6V 4AAA900mWh1.6V

Модели
4AAA900mWh1.6V
Скачать
Страница из 7
 
Conrad Electronic SE · Klaus-Conrad-Str.1 · 92240 Hirschau
 
14 Cycle Life 
             
Discharge to 1.3V at 55mA;  
Charge 120 minutes at 275mA constant 
current with a voltage holding at 1.9V;      
Constant voltage holding at 1.9V to 
charge 90 minutes until current drops to 
18mA;  
Rest for 15 minutes;  
Discharge to 1.2V at a constant current 
at 550mA;  
Repeat steps from   to   until the 
capacity drops to 60%. 
—
  The cycles life shall exceed 200 times  
15 Leak-proof 
test 
—
  Standard charge and store for 14 days 
under the following storage 
conditions
 33 ±3
Relative 
humidity: 80%±5%.  
—
  No leakage of electrolyte in liquid form 
shall be observed  
16 Vibration 
test 
—
  Store the cell more than 24 hours 
after standard charge, following 
vibration tests over an amplitude of 4 
mm (0.1575 inches) at a frequency of 
16.7 Hz(1000 cycles per minute) and 
repeated through any axes during 
60mins  
—
 
The subsequent fluctuation of open 
circuit voltage and internal impedance 
shall be less than 0.02  V and   5  mΩ 
respectively, and the surface of cell has 
no obvious change.
 
17 Free falling: 
(Drop) 
—
  Store the cell more than 24 hours 
after standard charge, following a 
drop test from 450mm (17.717 
inches ) on to a hard-wood board in a 
vertical axis 3 times . 
—
  The subsequent fluctuation of open 
circuit voltage and internal impedance 
shall be less than   0.02  V and   5   mΩ 
respectively, and the surface of cell has 
no obvious change. 
18 Safety 
testing 
—
  to store it for 1 hour after standard 
charged, and to make positive and 
negative electrode short-circuit with a 
wire with the section 0.75mm
min 
and shortest length, the short-circuit 
time is 1 hour 
—
  It shall not explode . However, leakage 
of electrolyte, external deformation or 
outer sleeve cracking is permitted.  
19. Safety Valve 
Start 
Performance 
(Over dis-
charging) 
—
  to be charged with  550 mA for 5 
hours 
—
  safety valve can work normally, no 
breakage, leakage, distortion and out 
package breakage are allowed 
20.  Safty Valve 
Start 
Performance 
(over 
charging) 
—
  to be charged with 550 mA for 5 
hours 
 
—
  No explosion, but leakage, distortion 
and out package breakage are allowed 
 
21.To discharge 
at low 
temperature 
—
  to be stored for 24 hours at 0 ±2 , 
and discharged at  110  mA at 
0 ±2
  
—
  discharge duration shall exceed  3  
hour(s)  30  min(s)