5 Charge 
Voltage 
—
  Following a period of discharge at 
110mA down to a terminal voltage , 
then standard charge, the cell voltage 
shall be tested at 5 minutes before 
finishing charging  
—
  The voltage shall be less than    2.0  V
6 Open circuit 
voltage: (O.C.V.) 
—
  After finished a standard charge 
period, the open circuit voltage of the 
cell shall be tested within 1 hour. 
 
—
  The O.C.V. shall exceed 1.8 V .               
7 Closed circuit 
voltage:  
(C.C.V.) 
—
  After finished a standard charge 
period, the closed circuit voltage of 
the cell shall be tested with a   0.86  
Ω Impedance loaded within 1hour  
—
  The C.C.V. shall exceed 1.6 V . 
8 Internal 
impedance 
—
  After finished a standard charge 
period, the internal impedance of the 
cell shall be tested within 1 hour  
—
  The internal impedance shall not be 
more than   38mΩ . 
9 capacity 
—
  After finished a standard charge 
period, the cell shall be tested within 
1 hour based discharged at 110  mA 
down to a terminal voltage of 1.3V  
—
  The capacity is equal or above the 
minimum capacity  
10 High Drain 
Discharge 
—
  To discharge at 550mA to 1.2V 
within 1 hour after finished standard 
charge  
—
  The Capacity is equal or above 54 
min  
11 Self-
discharge 
—
  Discharge at 110  mA  to a terminal 
voltage of 1.3V, then standard charge 
to put aside for 28 days , after 
discharge again at 110mA to 1.3V to 
test capacity.  
—
  The subsequent capacity shall not be 
less than  60%   of initial capacity.  
12 Over-charge 
—
  Following a period of discharge at    
110 mA down to a terminal voltage 
of 1.3V first standard charge and 
then charge for 48hrs at  55 mA by a 
constant voltage holding at 1.9V. 
Then discharge at 110mAh to test 
capacity . 
—
  No deformation , no leakage  
—
  Capacity not be less than minimum 
capacity 
13 Over-
discharge 
 
—
  Following a period of discharge at 
110  mA down to a terminal voltage 
of 1.3V, combine the cells with a 
0.86  Ωper cell load. After stored for 
a period of 24 hours, standard 
charged and then discharge at  110 
mA  
—
  No deformation  
—
  The subsequent capacity shall not be 
less than  80%  of rated capacity