Using the SINAMICS G110 
SINAMICS G110    Operating Instructions 
 
6SL3298-0AA11-0BP0 
51
 
4  Using the SINAMICS G110 
WARNINGS  
 
When operating electrical devices, it is impossible to avoid applying hazardous 
voltages to certain parts of the equipment. 
 
Emergency Stop facilities according to EN 60204 IEC 204 (VDE 0113) must 
remain operative in all operating modes of the control equipment.  Any 
disengagement of the Emergency Stop facility must not lead to uncontrolled or 
undefined restart. 
 
Wherever faults occurring in the control equipment can lead to substantial 
material damage or even grievous bodily injury (i.e. potentially dangerous 
faults), additional external precautions must be taken or facilities provided to 
ensure or enforce safe operation, even when a fault occurs (e.g. independent 
limit switches, mechanical interlocks, etc.). 
 
SINAMICS G110 inverters operate at high voltages. 
 
Certain parameter settings may cause the inverter to restart automatically after 
an input power failure. 
 
Motor parameters must be accurately configured for motor overload protection 
to operate correctly above 5 Hz. 
 
This equipment is capable of providing internal motor overload protection in 
accordance with UL508C. Refer to P0610 and P0335, I
2
t is ON by default.  
 
This equipment is suitable for use in a circuit capable of delivering not more 
than 10,000 symmetrical amperes (rms), for a maximum voltage of 230V, when 
protected by an H or K type fuse, a circuit breaker or self-protected combination 
motor controller. 
 
This equipment must not be used as an ‘emergency stop mechanism’ (see EN 
60204, 9.2.5.4) 
4.1  Frequency Setpoint (P1000)  
This parameter determines where the control signal for the frequency setpoint is 
obtained. The SINAMICS G110 has two default settings depending on the inverter 
variant. 
Analog Variant 
 
Default Value: 
2 – Terminal 9 
(AIN, 0…10 V) 
 
Other settings: 
see P1000 in the Parameter List 
 
USS Variant 
 
Default Value: 
5 – Terminals 8 and 9 
(RS485, USS protocol) 
 
Other settings: 
see P1000 in the Parameter List