Справочник Пользователя для Hamilton Sundstrand Company Fuel Metering Valves XVG

Скачать
Страница из 36
 
 
 
Register 
Number 
XVG/eXVG Parameter 
Name 
Write 
Access 
Corresponding CdA value 
Type 
Default 
Value 
6238 6239 
IDM_CDATBLPR7S14 
W4
 
0.618915975 U32
 
10383687 
6240 6241 
IDM_CDATBLPR8S0 
W4
 
0.017536998 U32
 
294222 
6242 6243 
IDM_CDATBLPR8S1 
W4
 
0.034340978 U32
 
576146 
6244 6245 
IDM_CDATBLPR8S2 
W4
 
0.045249999 U32
 
759169 
6246 6247 
IDM_CDATBLPR8S3 
W4
 
0.075426996 U32
 
1265455 
6248 6249 
IDM_CDATBLPR8S4 
W4
 
0.11294198 U32
 
1894852 
6250 6251 
IDM_CDATBLPR8S5 
W4
 
0.154013991 U32
 
2583926 
6252 6253 
IDM_CDATBLPR8S6 
W4
 
0.191594005 U32
 
3214414 
6254 6255 
IDM_CDATBLPR8S7 
W4
 
0.233344972 U32
 
3914879 
6256 6257 
IDM_CDATBLPR8S8 
W4
 
0.258821011 U32
 
4342296 
6258 6259 
IDM_CDATBLPR8S9 
W4
 
0.302787006 U32
 
5079923 
6260 6261 
IDM_CDATBLPR8S10 
W4
 
0.367821991 U32
 
6171029 
6262 6263 
IDM_CDATBLPR8S11 
W4
 
0.415814996 U32
 
6976218 
6264 6265 
IDM_CDATBLPR8S12 
W4
 
0.473388016 U32
 
7942133 
6266 6267 
IDM_CDATBLPR8S13 
W4
 
0.527272999 U32
 
8846173 
6268 6269 
IDM_CDATBLPR8S14 
W4
 
0.584348023 U32
 
9803733 
6270 6271 
IDM_CDATBLPR9S0 
W4
 
0.017027974 U32
 
285682 
6272 6273 
IDM_CDATBLPR9S1 
W4
 
0.033367991 U32
 
559822 
6274 6275 
IDM_CDATBLPR9S2 
W4
 
0.043686986 U32
 
732946 
6276 6267 
IDM_CDATBLPR9S3 
W4
 
0.073494017 U32
 
1233025 
6278 6269 
IDM_CDATBLPR9S4 
W4
 
0.107271016 U32
 
1799709 
6280 6281 
IDM_CDATBLPR9S5 
W4
 
0.150669992 U32
 
2527823 
6282 6283 
IDM_CDATBLPR9S6 
W4
 
0.183247983 U32
 
3074391 
6284 6285 
IDM_CDATBLPR9S7 
W4
 
0.231404006 U32
 
3882315 
6286 6287 
IDM_CDATBLPR9S8 
W4
 
0.25821501 U32
 
4332129 
6288 6289 
IDM_CDATBLPR9S9 
W4
 
0.281709015 U32
 
4726293 
6290 6291 
IDM_CDATBLPR9S10 
W4
 
0.344421983 U32
 
5778442 
6292 6293 
IDM_CDATBLPR9S11 
W4
 
0.391855001 U32
 
6574236 
6294 6295 
IDM_CDATBLPR9S12 
W4
 
0.445888996 U32
 
7480776 
6296 6297 
IDM_CDATBLPR9S13 
W4
 
0.501824021 U32
 
8419210 
6298 6299 
IDM_CDATBLPR9S14 
W4
 
0.544903994 U32
 
9141972 
 
Table 20:  CdA-Pressure Ratio Table Parameters 
 
 
9.1.6  Flow Limiting Mode Parameters 
 
The following table is used to define the Flow Limiting Mode schedule.  The 5-point 
Flow Limiting Mode Table defines the minimum and maximum flow limits by 
interpolation for a particular backpressure.  
 
Valid Flow Limiting Mode Table Backpressure values are in the range 0.0 - 498.0, 32 bit 
floating point format. Valid Flow Limiting Mode Table Minimum Flow values are in the 
range 0.0 - 20000.0, 32 bit floating point format. Valid Flow Limiting Mode Table 
Maximum Flow values are in the range 0.0 - 20000.0, 32 bit floating point format. 
 
 
 23