Справочник Пользователя для Hamilton Sundstrand Company Fuel Metering Valves XVG

Скачать
Страница из 36
 
 
 
Register 
Number 
XVG/eXVG Parameters 
Name 
Write 
Access 
Description Type 
3014 
IDM_ADCINPRES 
RO 
Input Pressure counts, range 0-4095 
U16
 
3015 
IDM_ADCAI0 
RO 
Analog Input 0 (demand), range 0-3413 
U16
 
3016 
IDM_ADCOUTPRES 
RO 
Output Pressure counts, range 0-4095 
U16
 
3017 
IDM_ADCAI1 
RO 
Analog Input 1 counts, range  0 – 4095  
U16
 
3018 IDM_ADCDELTAPRES 
RO Not 
used 
U16
 
3019 
IDM_ADCAI2 
RO 
Analog Input 2 counts, range 0 – 4095 
U16
 
3020 
IDM_ADCGASTEMP 
RO 
Gas Temperature counts 
U16
 
3021 
IDM_ADCAI3 
RO 
Analog Input 3 counts, range 0 – 4095 
U16
 
3022 IDM_ADCSOLTEMP 
RO 
Solenoid temp counts, not used 
U16
 
3023 
IDM_ADCAI4 
RO 
Analog Input 4 counts, range 0 – 4095 
U16
 
3024 
IDM_ADCMOTORCUR 
RO 
Motor Current counts, range 0 - 4095 
U16
 
3025 
IDM_ADCAI5 
RO 
Analog Input 5 counts, range 0 – 4095 
U16
 
3026 
IDM_FFAULTFLGS 
RO 
Fault Report Variable, not used 
U16
 
3027 
IDM_FVERSION 
RO 
Fault Report Variable, not used 
U16
 
3028 
IDM_FRUNTMMINS 
RO 
Fault Log, Run Time Minutes of fault log 
U16
 
3029 
IDM_FRUNTMSECS 
RO 
Fault Log, Run Time Seconds of fault log 
U16
 
3030 
IDM_SETUPERROR 
RO 
Setup Validation Error Code, 0 = No Errors 
U16
 
3031 
IDM_TESTFLAGS 
W3 
Test Flags (SW debug use only) 
U16
 
3032 
IDM_FMODE 
RO 
Fault Report Variable, not used 
U16
 
3033 IDM_CALFLAGS 
W1 
Calibration Flags:  
Bit0=Set Valve in Calibration State. 
The following bits active only in cal state: 
Bit1=Enable Feedback Override, 
Bit2=Set Solenoid Duty Cycle Out to 50% 
Bit3=Read ADC A raw cal voltage into 
IDM_ADCACALADC 
Bit4=Read ADC B raw cal voltage into 
IDM_ADCBCALADC 
Bit5=Write parameters to EEPROM Bit6=Reset 
IDM_TOTALHRS to 0 if parameter IDM_DATE = 
666 
U16
 
3034 
IDM_CALAOUT0 
W3 
Analog Output 0 DAC Value, counts 0-4095 
U16
 
3035 
IDM_ADCBCALADC 
RO 
ADC B 2.5V Ref Calibration counts 0-4095 
U16
 
3036 
IDM_AOUT1 
W3 
Analog Output 1 DAC Value, counts 0-4095 
U16
 
3037 
IDM_AOUT2 
W3 
Analog Output 2 DAC Value, counts 0-4095 
U16
 
 
 
 
 
 
3038 IDM_FIRMWAREVER 
RO Firmware 
Version 
U16
 
3039 
IDM_AOUT0 
RO 
AO0 DAC Value, counts 0-4095 
U16
 
3040 IDM_DIN0 
RO 
DI0 Value: (reserved for external Run/Stop)  
Bit0-Bit3=DI0-DI3 – only used if valve enters 
CAL_STATE 
U16
 
3041 IDM_DOUT0 
W3 
Digital Output 0 Value: (reserved for Fault Output) 
Bit0-Bit5=O0-O3, 485TXENA, 485TXENB – only 
valid if valve enters CAL_STATE, otherwise for SW 
test 
U16
 
 25